Chemical communications (Cambridge, England)

A peroxyoxalate-imprinted carbon dot gel as an intense and reusable chemiluminescence system under physiological conditions.

Wentong Fan, Qian Wu, Peng Wu, Xinfeng Zhang

Smart Analytical Science Research Centre, College of Materials and Chemistry & Chemical Engineering, Chengdu University of Technology, Chengdu 610059, China. zhangxinfeng09@cdut.cn. · Analytical and Testing Center, Sichuan University, 610064, China. Wupeng@scu.edu.cn.

Key points

From the paper's conclusion
  • The loading of peroxyoxalate into a molecularly imprinted gel greatly improved its hydrophilicity, achieving intense (70-fold enhancement) and persistent (> 1 h) chemiexcitation of carbon dots under physiological conditions.

Abstract

The loading of peroxyoxalate into a molecularly imprinted gel greatly improved its hydrophilicity, achieving intense (70-fold enhancement) and persistent (> 1 h) chemiexcitation of carbon dots under physiological conditions. Additionally, the gel could be readily refueled by reloading peroxyoxalate into the imprinted cavities. The system was quite suitable for chemiluminescent sensing.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A peroxyoxalate-imprinted carbon dot gel as an intense and reusable chemiluminescence system under physiological conditions — Science Skim