Beyond lateral flow: vertical flow immunoassays as thermodynamically assisted rapid diagnostics.
Shunmuga Nathan Shunmuga Nainar, Yen-Yi Chu, Hong-Cheu Lin, Yang-Hsiang Chan
Department of Materials Science and Engineering, National Yang Ming Chiao Tung University, Hsinchu, 30010, Taiwan. linhc@nycu.edu.tw. · Department of Applied Chemistry, National Yang Ming Chiao Tung University, Hsinchu, 30010, Taiwan. yhchan@nycu.edu.tw.
Key points
From the paper's conclusion- Lateral flow immunoassays (LFAs) dominate point-of-care diagnostics, however, their single-pass capillary architecture imposes four fundamental performance limitations: Damköhler-limited analyte capture (Da ≪ 1, contact time ∼1 s), an absent thermodynamic wash enabling high non-specific background, serial one-dimensional multiplexing with progressive analyte depletion, and the hook effect which ma
Abstract
Lateral flow immunoassays (LFAs) dominate point-of-care diagnostics, however, their single-pass capillary architecture imposes four fundamental performance limitations: Damköhler-limited analyte capture (Da ≪ 1, contact time ∼1 s), an absent thermodynamic wash enabling high non-specific background, serial one-dimensional multiplexing with progressive analyte depletion, and the hook effect which makes LFAs unreliable at higher analyte concentrations. A well-established alternative to this approach is vertical flow immunoassays (VFAs), which address these limitations through a stacked-membrane design that decouples convective delivery from immunoreaction kinetics. This configuration enables selective thermodynamic washing (99.94% specific retention and 45% non-specific removal in 60 s), supports two-dimensional capture arrays for scalable multiplexing and eliminates the hook effect through sequential surface chemistry. Nevertheless, chemistry-matched head-to-head comparisons have demonstrated up to ∼80-fold improvements in limits of detection relative to matched LFAs. In addition, coupling with surface-enhanced Raman spectroscopy, electrochemical transduction, nanoparticle amplification chemistry, and deep-learning inference has extended VFA sensitivity into the sub-picogram-per-milliliter range for high-sensitivity biomarker detection. This review surveys the physical-chemical basis of VFA performance and maps its applications across clinical diagnostics, food and environmental safety, and emerging detection paradigms. Furthermore, we examine the engineering barriers that have prevented a platform with a demonstrated 40-80-fold sensitivity advantage from achieving commercial scale. Finally, we summarize the remaining challenges and broader outlook for VFAs and outline a realistic pathway toward practical deployment and sustained clinical and industrial impact.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Transport-Reaction-Signal Coupling in Lateral Flow Assays for Next-Generation Point-of-Care Diagnostics.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
- Overcoming sensitivity limitations in lateral flow immunoassays for small-molecule detection: from tracer engineering to assay format innovation.Analytical and bioanalytical chemistry · 2026
- Recent advances in lateral flow immunoassay for virus detection: current achievements, challenges and future prospects.Talanta · 2026
- A Rational Optimization Approach for the Development of a Multiplexed Lateral Flow Immunoassay: Detection of Nonepithelial Ovarian Cancer Markers in Human SerumAdvanced Science · 2026
- Vertically Stacked Paper‐Based Microarray Device for High‐Throughput SERS Detection of Two Cancer BiomarkersSmall · 2026
- From sensitivity challenges to nanozyme-driven signal amplification in lateral flow immunoassays for biomarker detection.Journal of pharmaceutical and biomedical analysis · 2026