Analytical methods : advancing methods and applications

A beeswax-coated cellulose paper disc device: a sustainable microextraction platform for the determination of PDE-5 inhibitors in biological matrices.

Sonali, Himanshu Yadav, Amrita Yadav, Bharti Jain, Lalit Pratap Chandravanshi, Rajeev Jain, Sarah Alharthi

Department of Forensic Science, School of Allied Health Sciences, Sharda University, Greater Noida, 201306, India. bhartijain871@gmail.com. · Central Forensic Science Laboratory, Directorate of Forensic Science Services (DFSS), Ministry of Home Affairs (MHA), Dakshin Marg, Sector - 36A, Chandigarh, 160036, India. rajeev.jain-as@gov.in.

Key points

From the paper's conclusion
  • Therefore, for the first time, a simple, cost-effective, and sustainable rotating paper disc (RPD) device coated with natural beeswax (BW) was developed and validated for the simultaneous determination of sildenafil, avanafil and tadalafil in urine and blood samples.

Abstract

The sensitive detection of phosphodiesterase type 5 (PDE-5) inhibitor drugs in biological matrices is of paramount significance in forensic toxicology, especially in drug facilitated sexual assault cases involving these drugs. Therefore, for the first time, a simple, cost-effective, and sustainable rotating paper disc (RPD) device coated with natural beeswax (BW) was developed and validated for the simultaneous determination of sildenafil, avanafil and tadalafil in urine and blood samples. The analysis was performed by HPLC-PDA, with zolpidem employed as the internal standard (ISTD). Herein, the device harnesses the sorptive capacity of cellulose and beeswax, which together retain the analytes through hydrophobic interactions and hydrogen bonding between the beeswax (i.e. long-chain hydrocarbons, fatty acid esters, and hydroxyl-bearing constituents) and analyte (such as amine, amide, ether, and sulfonamide groups) components. The method showed good linearity over the range of 0.5-10 µg mL-1 for all analytes. The precision data showed high reliability, with intra-day repeatability of 2.1-6.8% and inter-day reproducibility of 5-8.5%, while the accuracy ranged from 92.9 to 104.1%. The validated procedure was successfully applied to real urine samples, confirming its practical forensic applicability. The sustainability of the method was assessed using the Multi-Color Assessment tool, yielding a Whiteness Score of 73.5%, attesting to the greenness and practicality of the method.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A beeswax-coated cellulose paper disc device: a sustainable microextraction platform for the determination of PDE-5 inhibitors in biological matrices — Science Skim