Defining selective chelation windows for Ca2+-Mg2+ discrimination in saline matrices: comparative performance of EDTA and EGTA.
Ghadeer H Albalawi, Ibtihaj Albalawi, Muhammad Ayaz, Fatimah A Alotaibi, Munawar Iqbal, Atheer G Almashhori, Fahad Ayesh Alharthi, Christopher Michael
Department of Chemistry, Faculty of Science, University of Tabuk, Tabuk 71491, Saudi Arabia. g_halbalawi@ut.edu.sa. · Artificial Intelligence and Sensing Technologies (AIST) Research Center, University of Tabuk, Tabuk 71491, Saudi Arabia.
Key points
From the paper's conclusion- Selective discrimination of Ca2+ from Mg2+ remains challenging in saline matrices because both ions exhibit similar coordination behaviour and their chelation responses can be altered by solution conditions.
Abstract
Selective discrimination of Ca2+ from Mg2+ remains challenging in saline matrices because both ions exhibit similar coordination behaviour and their chelation responses can be altered by solution conditions. EDTA and EGTA were systematically compared for Ca2+ and Mg2+ complexometric titration over 0-1000 ppm. The effects of pH (3-12), temperature (25-45 °C), NaCl (0-30 mM), KCl (0-19 000 mg L-1), SO42- (0-2700 mg L-1), and K+ (0-600 mg L-1) were evaluated in individual and equimolar Ca2+ : Mg2+ systems. Both chelators produced highly linear calibrations, but their responses differed markedly. EGTA increased Ca2+ calibration sensitivity by 32.9% relative to EDTA and showed substantially greater thermal stability. EDTA responded to both metals across pH 3-12, whereas EGTA produced no measurable Mg2+ endpoint at pH 3-7. Crucially, this Ca2+-selective response persisted in mixed Ca2+ : Mg2+ solutions containing chloride, sulphate, and potassium at the investigated concentrations. The study identifies an experimentally observed operational selectivity interval at pH 3-7, defined by differential endpoint detectability, in which Ca2+ remains measurable with EGTA while no stable visual Mg2+ endpoint is obtained under the investigated conditions. This matrix-resilient behaviour provides a practical basis for selective calcium analysis and future Ca2+/Mg2+ separation strategies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biodegradation and Photodegradation of Mg, Ca, Zn, and Cu Complexes of Biodegradable Chelating Agents (EDDS, HIDS, MGDA, and GLDA).ACS omega · 2026
- Extraction of divalent metal cations into nitrobenzene in the presence of commercially available magnesium ionophores and substituted cyclic bis ureaRadiochimica Acta · 2026
- Novel Scale for Clinical Identification of Adverse Magnesium/Calcium Imbalances: Applications and PerspectivesNutrients · 2025
- Forgotten electrolytes: magnesium and calcium flux during dialysis.Current opinion in nephrology and hypertension · 2026
- Ligand Preferences of Divalent Main‐Group and Transition Metal IonsJournal of Mass Spectrometry · 2026
- Mechanisms of Magnesium Transport Through Cell Membranes: The Primacy of the Free Divalent Cation and Implications for Magnesium Supplementation.Nutrients · 2026