ICP-OES determination of lanthanum in polysiloxanes: comparison of direct organic introduction and single reaction chamber microwave digestion.
Minsi Liang, Xuefei Cao, Biyin Qin, Linlin Jin, Shuangfei Hu
Instrumental Analysis & Research Center, Sun Yat-sen University, Guangzhou 510275, P.R. China. · School of Materials Science and Engineering, Sun Yat-Sen University, Guangzhou 510275, P.R. China.
Key points
From the paper's conclusion- Together, these two methods provide a reliable basis for selecting an appropriate sample preparation protocol.
Abstract
The lanthanum (La) content in polysiloxanes is a key parameter for evaluating catalyst performance, controlling product quality, and monitoring elemental residues. However, its accurate determination is hindered by the high viscosity, high organic content, and water insolubility of polysiloxanes. This study established two methods for determining La in polysiloxanes using inductively coupled plasma optical emission spectrometry (ICP-OES) combined with two sample preparation techniques: direct organic introduction (DOI) and single reaction chamber (SRC) microwave digestion. The analytical performance of both methods was compared. The results indicated that both methods exhibited excellent linearity in the range of 0-10 mg L-1, with correlation coefficients of 0.99996. The method detection limits (MDLs) were 0.0952 and 0.1800 mg kg-1, respectively. The relative standard deviations (RSDs) were below 3.4%, and the spiked recoveries ranged from 95.1% to 102.7%. Relative Bland-Altman analysis showed a small average difference between the two workflows for the four polysiloxane samples (mean relative difference: 0.75%). The overall AGREEprep scores of 0.47 and 0.20 for the DOI and SRC methods, respectively, indicate superior greenness for the DOI workflow. Featuring simpler operation, higher sample throughput, a lower validated MDL, and better environmental greenness, the DOI method is highly suitable for routine batch determinations of La in polysiloxanes. Conversely, SRC digestion serves as an effective complementary approach for cross-validation and for complex samples requiring organic matrix decomposition. Together, these two methods provide a reliable basis for selecting an appropriate sample preparation protocol.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- High-yield bio-polyols from sugarcane bagasse: process optimization, structural analysis, and application potential.Environmental science and pollution research international · 2026
- Environmental Applications of Acid-Leached Residue Obtained during Lanthanum Recovery from Spent Cracking CatalystACS Sustainable Resource Management · 2026
- Polyhedral Oligomeric Silsesquioxane-Based Ionic Liquids: Syntheses, Properties, and ApplicationsChemical Reviews · 2026
- Expanding the Toolbox of Rare Earth Quantification for Bioaccumulation Studies: Selective Lanthanide Determination Using ICP-OES and Sensitized Luminescence for High Throughput Microbial Screening.Analytical chemistry · 2026
- Catalyst-Free Hydrolytic Polycondensation of Phenyltrimethoxysilane Under Ultrasonic Irradiation.Polymers · 2026
- Ratiometric Luminescence Sensing of Perfluorooctanoic Acid with an Amino-Functionalized Lanthanide Metal–Organic Framework: An Integrated Undergraduate Laboratory ExperimentJournal of Chemical Education · 2026