A reference-standard-free semi-quantitative workflow for pesticide residue analysis by LC-QTOF/MS using machine learning-based prediction of ionization efficiency: application to banana screening.
Kaixuan Tong, Tongxin Zhi, Meiling Lu, Xingqiang Wu, Yujie Xie, Mengjie Shi, Hui Chen
China National Research Center for Food Safety Inspection and Testing, Beijing 100045, China. ciqhuichen@163.com. · Chinese Academy of Quality and Inspection & Testing, Beijing 100176, China.
Key points
From the paper's conclusion- The results demonstrate the practical potential of the proposed workflow for providing reliable concentration level information in the absence of reference standards.
Abstract
After screening for suspected target pesticides using liquid chromatography quadrupole time-of-flight mass spectrometry (LC-QTOF/MS), quantitation still largely depends on reference standards. A reference-standard-free semi-quantitative workflow was developed to predict analyte concentrations directly from LC-QTOF/MS signal intensities by modeling ionization efficiency (IE) using machine learning. The relative ionization efficiencies of 289 pesticides in a banana matrix were measured under 126 different mobile phase compositions, generating a training dataset comprising 3397 log IE values. PaDEL-derived molecular descriptors were combined with mobile phase physicochemical parameters, including viscosity, surface tension, and polarity index, as input features. Eleven regression algorithms were evaluated, and Gradient Boosting Regression (GBR) was selected as the optimal model. The final model was further validated using banana samples from the 2024 EU proficiency test for fruits and vegetables (EUPT-FV24). The GBR model achieved a test-set R2 of 0.756, with a maximum error of 4.81-fold. SHAP analysis identified surface tension, polarity index, and average molecular weight as the top contributors, consistent with the principles of electrospray ionization. In the EUPT-FV-24 application, the concentrations of 11 detected pesticides were estimated with a median error of 2.74-fold and a mean error of 3.42-fold, with all predictions falling within the correct order of magnitude. The results demonstrate the practical potential of the proposed workflow for providing reliable concentration level information in the absence of reference standards. This approach provides a practical solution for semi-quantification in non-targeted screening, with further improvements expected through expanded training coverage and the incorporation of uncertainty quantification.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Machine Learning-Enhanced LC-HRMS Workflows for Suspect and Nontargeted Screening of Pesticide Residues in Fruits and Vegetables.Analytical chemistry · 2026
- Robust Chemometric Machine Learning Framework for Screening-Stage Triage in Antidoping Urine Analysis.Analytical chemistry · 2026
- Emzing: A Deep Learning-Enabled Software Suite for End-to-End Analysis of High-Resolution LC-MS Metabolomics Data.Analytical chemistry · 2026
- AI redefines mass spectrometry chemicals identification: retention time prediction in metabolomics and for a Human Exposome ProjectFrontiers in Public Health · 2025
- Geographic authentication of premium tobacco extracts using machine learning models trained on LC-HRMS fingerprints.Frontiers in molecular biosciences · 2026
- From Analytical Detection to Spatial Prediction: LC–MS and Machine Learning Approaches for Glyphosate Monitoring in Interconnected Land–Soil–Water SystemsLand · 2026