Analytical methods : advancing methods and applications

Selective and sensitive colorimetric detection of copper(II) using methylthiazole-quinolinol based sensor: application in real samples and its experimental and DFT studies.

Sareh Sadat Abolghasemi, Hadi Fallah Moafi, Seyed Hossein Mousavi

Department of Inorganic Chemistry, Faculty of Chemistry, University of Guilan, Rasht, Iran. fallah.m@guilan.ac.ir.

Key points

From the paper's conclusion
  • The unique features of the MTAMQ sensor, including naked-eye detection of copper ions in environmental samples without the need for specialized equipment, real-time analysis, cost-effectiveness, simple operation, rapid response, high stability under different conditions, and excellent selectivity and sensitivity, make it a promising alternative to previously reported colorimetric sensors.

Abstract

A novel methylthiazole-quinolinol-based sensor (MTAMQ) named (E)-2-methyl-5-((4-methylthiazol-2-yl)diazenyl)quinolin-8-ol was synthesized. In the presence of copper(II) ions (Cu2+), the MTAMQ sensor exhibits a stable color change from yellow to red. The MTAMQ sensor displayed a linear response toward Cu2+ ions over the concentration range of 0.10 to 55 µM (0.006 to 3.5 mg L-1), with a detection limit of 103.93 nM (6.60 µg L-1). The binding constant of the MTAMQ-Cu2+ complex was 1.41 × 104 M-1, and the stoichiometric ratio of complex formation was 1 : 1. Using EDTA, the MTAMQ sensor can be recycled and reused up to 4 times. Density functional theory (DFT) calculations were conducted for the MTAMQ sensor and the MTAMQ-Cu2+ complex. The MTAMQ sensor was successfully used to detect and quantify Cu2+ ions in various foodstuff and water samples, and the results were very close to those of the atomic absorption spectroscopy (AAS) method. To enable the detection of Cu2+ ions without the need for a complex device, paper test strips were prepared using the MTAMQ sensor and offered successful results. The unique features of the MTAMQ sensor, including naked-eye detection of copper ions in environmental samples without the need for specialized equipment, real-time analysis, cost-effectiveness, simple operation, rapid response, high stability under different conditions, and excellent selectivity and sensitivity, make it a promising alternative to previously reported colorimetric sensors.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers