Analytical methods : advancing methods and applications

Establishment of a time-resolved fluorescence immunoassay for FGF23 based on the capture of the intermediate region spanning the cleavage site combined with dual-epitope recognition.

Mengxuan Zhao, Han Bao, Zhijian Zhang, Shangbin Kao, Tianyu Zheng, Jiajun Fang, Yuan Qin, Biao Huang,

College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, China. jswxhb@163.com. · Department of Nephrology, The Affiliated Wuxi People's Hospital of Nanjing Medical University, Wuxi People's Hospital, Wuxi Medical Center, Nanjing Medical University, Jiangsu, China. wangliang_wuxi@126.com.

Key points

From the paper's conclusion
  • In this study, we established a highly sensitive, time-resolved fluorescence immunoassay platform based on an intermediate region capture strategy spanning the FGF23 cleavage site, combined with N-terminal and C-terminal epitope antibody detection.

Abstract

Hyperphosphatemia is a common complication in dialysis patients that increases the risk of cardiovascular events, vascular calcification, and mortality. Fibroblast growth factor 23 (FGF23) is a key hormone that regulates phosphorus homeostasis, and elevated levels of FGF23 are closely associated with the progression of CKD-MBD and poor prognosis in patients with ESRD. However, circulating FGF23 cleavage fragments may interfere with conventional immunoassays, affecting the accurate quantification of intact FGF23 (iFGF23). In this study, we established a highly sensitive, time-resolved fluorescence immunoassay platform based on an intermediate region capture strategy spanning the FGF23 cleavage site, combined with N-terminal and C-terminal epitope antibody detection. This method has a linear range of 75-1200 pg mL-1, with intra-assay and inter-assay coefficients of variation of 5.85-8.54% and 5.25-9.22% and recovery rates ranging from 94.61% to 103.43%. Cleavage fragment interference assays showed that nFGF23 and cFGF23 caused no significant interference. TRFIA results were highly correlated with those from a commercial ELISA assay (Spearman's ρ = 0.9617, P < 0.0001). Clinical application results showed that serum iFGF23 levels in ESRD patients were significantly higher than those in healthy controls [240.8 (153.9-418.9) pg mL-1vs. 85.89 (76.82-103.9) pg mL-1, P < 0.0001]. The TRFIA method established in this study, which combines capture of the intermediate region spanning the FGF23 cleavage site with dual-end recognition, can effectively reduce fragment interference and enable highly specific detection of iFGF23, providing a new diagnostic strategy for iFGF23 monitoring in ESRD patients and for CKD-MBD research.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers