Chemiluminescence and electrochemiluminescence biosensors for cancer biomarker detection: analytical advances, liquid-biopsy applications, and translational challenges.
Asif Ahmad Bhat, Shivkanya Fuloria, Riya Thapa, Nina Varghese, Rohini Karunakaran, Sumita Bhatia, Kamal Narain, Anupam Biswas,
Faculty of Pharmacy, AIMST University, Bedong, Kedah, Malaysia. neerajkumarfuloria1@gmail.com. · Faculty of Medicine, AIMST University, Bedong, Kedah 08100, Malaysia.
Key points
From the paper's conclusion- Automated sample-to-result CL/ECL systems, harmonized reference materials, prospective multicenter validation, and evidence that improved analytical sensitivity translates into clinically meaningful benefits in cancer detection, diagnosis, monitoring, and/or treatment selection are required for future progress.
Abstract
Biosensors based on chemiluminescence (CL) and electrochemiluminescence (ECL) have demonstrated high sensitivity for the detection of cancer biomarkers, including proteins, nucleic acids, extracellular vesicles, exosomes, intact tumor cells, and circulating tumor cells. CL and ECL provide low optical background and compatibility with enzymatic, nucleic-acid, nanomaterial-based, and nanozyme-mediated amplification strategies, while ECL additionally enables electrochemically controlled signal generation and compatibility with miniaturized electrode formats. This review critically examines how CL and ECL sensing principles, recognition and amplification strategies, nanomaterial-assisted architectures, and multiplexed formats are applied across major liquid-biopsy analyte classes, including proteins, nucleic acids, extracellular vesicles and exosomal cargo, intact tumor cells, and circulating tumor cells, and evaluates the analytical trade-offs that influence their clinical translation. Special attention is given to analytical performance parameters, including the limit of detection, linear range, recovery, selectivity, reproducibility, and storage stability, and comparisons with enzyme-linked immunosorbent assay (ELISA), automated immunoassays, quantitative PCR, digital PCR (dPCR), and sequencing. The reported detection limits of many experimental platforms reach femtomolar or even attomolar concentrations; however, the data are often obtained from buffer solutions, spiked specimens, or small, single-center cohorts and are therefore difficult to compare because of differences in the target, matrix, amplification scheme, and calibration procedure. Complex fabrication, limited standardization, insufficient interference testing, the absence of traceable calibrators, variable pre-analytical workflows, and the absence of external validation of diagnostic decision thresholds also limit clinical translation. Automated sample-to-result CL/ECL systems, harmonized reference materials, prospective multicenter validation, and evidence that improved analytical sensitivity translates into clinically meaningful benefits in cancer detection, diagnosis, monitoring, and/or treatment selection are required for future progress.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Advanced Electrochemiluminescence DNA Aptasensor for Sensitive Detection of Cancer Biomarkers.Advanced pharmaceutical bulletin · 2026
- Electrochemical Biosensors for Circulating Tumor Cells and ctDNA: Emerging Strategies for Precision Oncology.Annals of biomedical engineering · 2026
- Emerging liquid biopsy tools to analyse cancer biomarkers: electrochemical sensors and extracellular vesicle analysisBiochemical Society Transactions · 2026
- Electrochemical Biosensors for Cancer Diagnosis and Prognosis Using Protein Biomarkers: Current Trends, Advances, and Clinical Translation PotentialSensors · 2026
- Advances in Electrochemical Biosensors for Circulating Tumor Cell DetectionChemBioChem · 2026
- Potential-Resolved Electrochemiluminescence and Its Application in Disease Biomarker DetectionBiosensors · 2025