Sm2O3 confinement of gold nanoclusters for the sensitive fluorescence detection of triclopyr.
Yunjing Zang, Songrui Li, Yiran Zhang, Hetong Wang, Dawei Zhang, Qiong Jia
College of Chemistry, Jilin University, Changchun 130012, China. z_dw@jlu.edu.cn.
Key points
From the paper's conclusion- A novel fluorescent sensor (MUA-AuNCs@Sm2O3) was constructed by confining gold nanoclusters within Sm2O3 and employed for the detection of the organophosphorus pesticide triclopyr.
- Based on the change in fluorescence intensity, the sensitive detection of triclopyr was achieved in the range of 2.5-140.0 µg L-1 with a limit of detection (LOD) of 0.82 µg L-1.
- The probe was successfully used for the detection of triclopyr in soil, tea, and spinach samples, and the accuracy was assessed through recovery experiments.
Abstract
In this study, a novel fluorescent sensor (MUA-AuNCs@Sm2O3) was constructed by confining gold nanoclusters within Sm2O3 and employed for the detection of the organophosphorus pesticide triclopyr. The probe interacted with triclopyr through a combination of static quenching and dynamic quenching, which led to fluorescence quenching. Based on the change in fluorescence intensity, the sensitive detection of triclopyr was achieved in the range of 2.5-140.0 µg L-1 with a limit of detection (LOD) of 0.82 µg L-1. The probe was successfully used for the detection of triclopyr in soil, tea, and spinach samples, and the accuracy was assessed through recovery experiments. All results verified the excellent practicability and reliability of the constructed fluorescent sensor. This study offers a promising alternative approach for the rapid and portable detection of pesticides in practical samples.
Read the paper
Discussion · 1
Science Skim's AI key points, plus readers' public thoughts
- A novel fluorescent sensor (MUA-AuNCs@Sm2O3) was constructed by confining gold nanoclusters within Sm2O3 and employed for the detection of the organophosphorus pesticide triclopyr.
- Based on the change in fluorescence intensity, the sensitive detection of triclopyr was achieved in the range of 2.5-140.0 µg L-1 with a limit of detection (LOD) of 0.82 µg L-1.
- The probe was successfully used for the detection of triclopyr in soil, tea, and spinach samples, and the accuracy was assessed through recovery experiments.
Readers' thoughts
No reader thoughts yet.
Related papers
- Leonurus cardiaca L. Polysaccharide-Stabilized Palladium-Gold Nanoparticles and Fluorescent Carbon Dots for Selective and Dual-Mode Detection of Pesticide Glyphosate.Biomolecules · 2026
- Facile synthesis of a novel fluorescent Au nanoclusters using sunset yellow as template and their application in multiple substances detection.Talanta · 2026
- Peroxide-like enzymes with fluorescent properties for colorimetric/fluorescent dual-mode detection and degradation of organophosphorus pesticide.Talanta · 2026
- Silver doping induced fluorescence enhancement of gold nanoclusters combined with machine learning for detection of quercetin.Analytical and bioanalytical chemistry · 2026
- Competitive displacement fluorescent aptasensor using UiO-66@AuNPs for sensitive detection of acetamiprid in tea.Analytical methods : advancing methods and applications · 2026
- A ratiometric fluorescence sensor based on Eu3+@tetrafluorosuccinic acid functionalized UiO-67: Enhancing the detection performance of ofloxacin through pre-concentration effect.Food chemistry · 2026