Bromazepam distribution in a solid dosage form studied by time-of-flight secondary ion mass spectrometry.
Matjaž Finšgar
Faculty of Chemistry and Chemical Engineering, University of Maribor, Smetanova ulica 17, 2000 Maribor, Slovenia. matjaz.finsgar@um.si.
Key points
From the paper's conclusion- This work presents the surface and subsurface analysis of a bromazepam (BRZ) tablet using three-dimensional (3D) profilometry, atomic force microscopy, X-ray photoelectron spectroscopy, and time-of-flight secondary ion mass spectrometry.
Abstract
This work presents the surface and subsurface analysis of a bromazepam (BRZ) tablet using three-dimensional (3D) profilometry, atomic force microscopy, X-ray photoelectron spectroscopy, and time-of-flight secondary ion mass spectrometry. Profilometry and AFM showed that the tablet surface was heterogeneous, with an average mean surface roughness value of 66.98 ± 5.69 µm. XPS confirmed the expected elemental composition of the BRZ standard (a compressed powder of the reference standard). On the other hand, Br-related signals were not detected in the BRZ tablet due to its low BRZ content and the XPS technique's too high detection limit. Therefore, ToF-SIMS was the main technique for BRZ determination. Positive-ion spectra of the BRZ standard were used to assign characteristic BRZ-related ions. For imaging, negative-ion signals were more suitable. The 79Br- and 81Br- ions were selected as BRZ markers and were verified by their spatial agreement with the deprotonated molecular ion C14H9BrN3O-. Two-dimensional (2D) imaging was performed using delayed-extraction analyzer mode combined with fast-imaging liquid-metal-ion-gun mode, yielding high-lateral-resolution images of localized BRZ-rich surface areas. 3D ToF-SIMS imaging was performed using a 10 keV Ar2000+ gas cluster ion beam for sputtering to a depth of approximately 13 µm. The 2D and 3D ToF-SIMS data showed that BRZ was not homogeneously distributed but was present in discrete BRZ-rich areas within the excipient-rich tablet matrix. These results demonstrate that ToF-SIMS is suitable for determining and imaging low-dose BRZ in solid pharmaceutical formulations where XPS lacks sufficient surface sensitivity.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Histology-Guided Serial-Section Framework for Quasi-3D ToF-SIMS Molecular Imaging of Rat Brain Lipid Ions.Analytical chemistry · 2026
- MALDI-TOF Mass Spectrometry Imaging for Spatially Resolved Degradation Profiling of Solid Formulations.Analytical chemistry · 2026
- MALDI MSI Workflow for Pharmaceutical Tablets: Toward a Reproducible Strategy for High-Resolution Imaging.Journal of the American Society for Mass Spectrometry · 2026
- Surface chemical differentiation of fingermark samples by ToF-SIMS and multivariate statistical analysis.Analytical methods : advancing methods and applications · 2026
- Improved Analysis and Characterization of Brominated Vegetable Oil in Multiple Beverages Using LC-MS/MS and LC-HRMS.Journal of agricultural and food chemistry · 2026
- A High-Throughput Workflow for High-Content Microplate-Based Assays via Mass Spectrometry Imaging.Analytical chemistry · 2026