The electrochemiluminescence immunosensor based on the Ce(III,IV)-MOF dual-function platform is used for the ultra-sensitive detection of AFP.
Li Liu, Haoyi Ren, Tiantian Ji, Shushu Li, Hongyu Xue, Chenglin Hong, Hongling Li
School of Chemistry and Chemical Engineering/State Key Laboratory Incubation Base for Green Processing of Chemical Engineering, Shihezi University, Shihezi 832003, PR China. hcl_tea@shzu.edu.cn.
Key points
From the paper's conclusion- The sensor developed using this strategy showed a broad linear range (1 × 10-4 ng mL-1-100 ng mL-1) and a low detection limit (0.036 pg mL-1), together with excellent selectivity, stability, and reproducibility.
Abstract
To address the challenges of unstable immobilization of tris(2,2'-bipyridine) ruthenium(II) (Ru(bpy)32+) and inefficient generation of the tri-n-propylamine radical (TPrA˙) in the Ru(bpy)32+/TPrA electrochemiluminescence (ECL) system, a novel dual-function strategy using a mixed-valence cerium metal-organic framework (Ce(III,IV)-MOF) was introduced in this study. The Ce(III,IV)-MOF was employed both as a scaffold for Ru(bpy)32+ and as a co-reaction catalyst. The three-dimensional structure of the Ce(III,IV)-MOF provides a stable environment for Ru(bpy)32+, while the Ce(III)/Ce(IV) redox pair within the framework facilitates TPrA oxidation through reversible single-electron transfer, thereby enhancing TPrA˙ generation. This design co-localizes the luminophore and catalytic centers within a single framework, reducing shortening the electron-transfer distance between Ru(bpy)32+ and the TPrA˙ site, and consequently enhancing the ECL performance of the Ru(bpy)32+/TPrA system. Compared with single-valence MOFs and their physically mixed MOF composites, the ECL performance of the Ru@Ce (III,IV)-MOF/TPrA system is significantly improved, with the maximum ECL signal amplification factor reaching up to 2.7 times. The sensor developed using this strategy showed a broad linear range (1 × 10-4 ng mL-1-100 ng mL-1) and a low detection limit (0.036 pg mL-1), together with excellent selectivity, stability, and reproducibility. This strategy provides a promising route for constructing multifunctional MOF-based ECL sensors for sensitive tumor biomarker detection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Metal-Organic Framework-Based Electrochemiluminescence Immunosensor with Dual Quenching via Resonance Energy Transfer and Radical Scavenging.ACS omega · 2026
- Efficient Electrochemiluminescent Ce−Cu Bimetal−Organic Framework with Self-Catalytic AIECL Performance for Constructing Biosensing Platform Integrated with an Allosteric Stem-Loop DNAzyme-Localized CHA Cyclic Amplification StrategyAnalytical Chemistry · 2026
- Supramolecular Ru-based metal-covalent organic framework with enhanced electron transfer enabling efficient kanamycin detection.Mikrochimica acta · 2026
- Synergistic sensitization between Rh-MOF and Ru(bpy)32+ driving superior electrochemiluminescence performance for selective L-proline detection.Mikrochimica acta · 2026
- MOF-regulated aggregation-induced electrochemiluminescence for machine learning-assisted aptasensing of cancer marker.Talanta · 2026
- Highly Electroactive Ti3C2Tx MXenes@TiO2-PdNCs as an Efficient Coreaction Accelerator for Amplifying the Aggregation-Induced Electrochemiluminescence of Self-Enhanced Cu:Gd-TCPE-MOF in Biomarker Immunoassays.Analytical chemistry · 2026