Magnetic molecularly imprinted polymer for selective extraction and untargeted monitoring of patulin and its metabolites in apple juices by UHPLC-HRMS.
María García-Nicolás, Alba Jiménez-López, Natalia Arroyo-Manzanares, Natalia Campillo, Pilar Viñas
Department of Analytical Chemistry, Faculty of Chemistry, Regional Campus of International Excellence "Campus Mare Nostrum", University of Murcia, E-30100 Murcia, Spain. natalia.arroyo@um.es.
Key points
From the paper's conclusion- The proposed magnetic molecularly imprinted polymer-based workflow represents a significant advancement for both regulatory monitoring and broader mycotoxin derivative screening.
Abstract
Patulin is a mycotoxin commonly found in apple-derived products, posing significant risks to consumer health. In response to increasing regulatory demands and analytical challenges, this study presents a novel sample preparation strategy for the determination of patulin and its metabolites in apple juice using dispersive magnetic solid-phase microextraction with a magnetic molecularly imprinted polymer, combined with liquid chromatography-high resolution mass spectrometry. The patulin-selective commercial molecularly imprinted polymer was magnetized, yielding a sorbent with high specificity and straightforward handling. The material was characterized by energy dispersive spectroscopy and field emission scanning electron microscopy, confirming successful magnetization and appropriate morphology. The method achieved excellent linearity (1-100 ng mL-1; R2 = 0.989), with detection and quantification limits of 0.32 ng mL-1 and 1.09 ng mL-1, respectively, both significantly below the maximum levels established by European legislation. Validation confirmed satisfactory trueness (96-106% recovery) and precision (RSD ≤ 7.4%). Application to ten commercial juices revealed the presence of PAT at 4.8 ± 0.4 ng mL-1 in one sample. Untargeted high resolution mass spectrometry analysis further enabled the tentative identification of hydroascladiol and ascladiol as patulin metabolites in three juices. The proposed magnetic molecularly imprinted polymer-based workflow represents a significant advancement for both regulatory monitoring and broader mycotoxin derivative screening.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Smartphone-assisted molecularly imprinted fluorescent hydrogel microneedles for on-site screening of patulin on fruit surfaces.Talanta · 2026
- Occurrence and Dietary Exposure Assessment of Patulin and Major Alternaria Toxins in Commercial Infant Fruit Purées from Italian and Spanish Markets Using Targeted Analysis and Suspect Screening.Toxins · 2026
- Computationally Guided Design of Magnetic Molecularly Imprinted Polymers for the Selective Determination of Pyrethroid Pesticides in Foods.Journal of separation science · 2026
- Covalent Michael-type recognition-based dual-mode sensing platform using thiol-functionalized nitrogen-doped carbon dots and Fe-MOF nanozyme for ultrasensitive patulin detection.Mikrochimica acta · 2026
- Identification of patulin-producing Penicillium isolates from decayed apples, their patulin production profiles, and the feasibility of high-purity patulin preparation.Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment · 2026
- Synthesis of urea-functionalized magnetic porous organic framework for the analysis of triphenylmethane dyes in foods using MSPE-HPLC-MS/MS.Food chemistry · 2026