Electrochemical sensor modified with nickel-doped zinc oxide nanoparticles for sensitive monitoring of rizatriptan benzoate in human plasma.
Mohamed Ahmed Elsayed, Mohamed A Saeed, Amr M Mahmoud, Noha S Mostafa
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Fayoum University, Faiyum, Egypt. · Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr El Aini, Cairo 11562, Egypt. amr.bekhet@pharma.cu.edu.eg.
Key points
From the paper's conclusion- In this work, a sustainable, novel and cost-effective electrochemical sensor was established for the sensitive determination of RZB by modifying a carbon paste electrode (CPE) with nickel-doped zinc oxide nanoparticles (Ni-ZnO NPs) via a simple precipitation procedure.
Abstract
Rizatriptan benzoate (RZB), a first-line therapy for the acute treatment of migraine, requires sensitive and reliable monitoring in pharmaceutical formulations and biological matrices to ensure effective quality control and therapeutic drug monitoring. In this work, a sustainable, novel and cost-effective electrochemical sensor was established for the sensitive determination of RZB by modifying a carbon paste electrode (CPE) with nickel-doped zinc oxide nanoparticles (Ni-ZnO NPs) via a simple precipitation procedure. The prepared nanoparticles were characterized using X-ray diffraction (XRD), scanning electron microscopy (SEM) coupled with energy-dispersive X-ray spectroscopy (EDX), and Fourier-transform infrared spectroscopy (FT-IR), confirming their crystalline nature. The Ni-ZnO/CPE demonstrated remarkable electrocatalytic efficiency for RZB oxidation in phosphate buffer solution at pH 6.0. Utilizing differential pulse voltammetry, the sensor showed linearity over the concentration interval of 0.04-20 µM. Moreover, the sensor showed excellent repeatability and intermediate precision, with relative standard deviation (RSD) values below 1.5%. The sensor was effectively employed for RZB detection in tablets and human plasma, exhibiting adequate recovery rates of 99.71-101.26% and 100.22-101.26%, respectively. The suggested approach revealed favorable analytical performance compared with previously reported DPV procedures, offering a lower limit of detection of 0.01 µM and enhanced sensitivity. Moreover, this is the first reported electrochemical method for RZB that combines drug determination with a comprehensive environmental assessment. Environmental sustainability was assessed utilizing modern metrics for greenness, blueness, and whiteness, and the findings revealed an excellent eco-profile with strong compliance with the principles of green analytical chemistry.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- ZnO-modified carbon paste electrode for electrochemical sensing of dopamine in the presence of tyrosineADMET & DMPK · 2025
- Point-of-care nano zinc oxide carbon paste sensor for non-invasive determination of clozapine in saliva samplesBMC Chemistry · 2025
- Electrochemical determination of terbutaline using a SnO2 nanoparticle-modified carbon paste electrode.Turkish journal of chemistry · 2026
- A molecularly imprinted electrochemical sensor based on dual functional monomers for selective determination of nimodipineAnalytical Methods · 2026
- Sulfur-doped graphitic carbon nitride/cerium tungstate nanocomposites for ultrasensitive dopamine sensing in mouse striatal tissue.Talanta · 2026
- Rapid carbamazepine detection by means of a disposable electrochemical sensor based on a molecularly imprinted polymerTalanta · 2025