Heterostructured CuO/g-C3N4 nanocomposite-based molecularly imprinted electrochemical sensor for the detection of microcystin-LR.
Qingdi Yang, Jinfei Yi, Shuang Zhao, Fang Pu, Yanli Zhang, Lianxun Gao, Hongbin Wang, Wenrong Yang,
Functional Nanomaterial-based Chemical and Biological Sensing Technology Innovation Team of Department of Education of Yunnan Province, Yunnan Minzu University, Kunming 650504, P. R. China. ylzhang@ymu.edu.cn. · School of Life and Environmental Sciences, Deakin University, Geelong, VIC 3217, Australia.
Key points
From the paper's conclusion- A molecularly imprinted electrochemical sensor was developed for the detection of MC-LR based on a copper oxide and graphitic carbon nitride (CuO/g-C3N4) nanocomposite.
Abstract
Microcystin-LR (MC-LR) is one of the most toxic liver-damaging toxins that can be produced during cyanobacteria blooms and poses a threat to human health, emphasizing the need for new detection methods. A molecularly imprinted electrochemical sensor was developed for the detection of MC-LR based on a copper oxide and graphitic carbon nitride (CuO/g-C3N4) nanocomposite. CuO/g-C3N4 nanocomposite is synthesized using an in situ growth method wherein the CuO nanoparticles are homogenously dispersed on g-C3N4 nanosheets, forming a CuO/g-C3N4 p-n heterojunction. This composite effectively facilitates the charge transfer process while significantly enhancing the detection signal intensity. A molecularly imprinted polymer (MIP) film was directly prepared on the surface of a CuO/g-C3N4 coated glassy carbon electrode via free-radical polymerization using MC-LR as a template along with suitable functional monomers. Following template removal, the resulting molecularly imprinted cavities within the MIP demonstrated high specificity for MC-LR recognition. The MIP-based electrochemical sensor exhibited an excellent linear response and high sensitivity for MC-LR detection over a broad concentration range of 0.2-300 ng mL-1, achieving a low limit of detection (LOD) of 0.08 ng mL-1 (calculated using 3σ/S). The sensor demonstrated excellent selectivity, reproducibility, and stability for the rapid and ultrasensitive detection of MC-LR, thereby providing a critical analytical capability for safeguarding environmental quality and public health.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Competitive Antifouling Sensor with a High-Efficiency Cluster for Environmental Pollution Trace AnalysisAnalytical Chemistry · 2025
- Guanidinium-driven fluorescence detection of microcystins using carbon dot embedded silica nanoparticles.iScience · 2026
- Electrochemical detection of catechol and hydroquinone based on MXene/MIL-101(Cr)/MWCNTs-COOH.Analytical methods : advancing methods and applications · 2026
- Pendimethalin imprinted electrochemical sensor based on CuO-Bi2MoO6 nanocomposite and pendimethalin detection in real samplesMicrochimica Acta · 2026
- A simple UiO-66-NH₂@MWCNTs based electrochemical sensor for the sensitive detection of metronidazoleADMET & DMPK · 2025
- Development of Carbofuran Imprinted Electrochemical Sensor Based on Carbon Black-Graphitic Carbon Nitride Nanocomposite and Carbofuran Detection in Orange Juice Samples.Foods (Basel, Switzerland) · 2026