Photochemical vapor generation for the determination of chloride in fuel ethanol by ICP-MS/MS.
Gustavo R Bitencourt, Ralph E Sturgeon, Erico M M Flores, Paola A Mello
Departamento de Química, Universidade Federal de Santa Maria, Santa Maria, RS, 97105-900, Brazil. paola.mello@ufsm.br. · National Research Council Canada, Metrology Research Centre, Ottawa, ON, K1A 0R6, Canada.
Key points
From the paper's conclusion- A photochemical vapor generation (PVG) analyte introduction method was developed for the determination of Cl- in fuel ethanol by triple quadrupole inductively coupled plasma mass spectrometry (ICP-MS/MS) to overcome the spectral and matrix interferences that hinder the determination of Cl-.
Abstract
The global trend of increasing ethanol demand requires implementation of rigorous quality control protocols, and the presence of chloride has been a matter of concern for regulatory agencies. A photochemical vapor generation (PVG) analyte introduction method was developed for the determination of Cl- in fuel ethanol by triple quadrupole inductively coupled plasma mass spectrometry (ICP-MS/MS) to overcome the spectral and matrix interferences that hinder the determination of Cl-. The use of ICP-MS/MS with a mass-shift approach using O2 as the reaction gas (35Cl+ → 35Cl16O+) significantly reduced the background compared to conventional single quadrupole ICP-MS. The presence of only ethanol was insufficient to photogenerate volatile chlorine species. On the other hand, an evaluation of auxiliary agents for PVG of Cl- (especially, but not limited to, Cu) revealed that the addition of copper acetate (CuAc2) to the ethanolic medium enhanced CH3Cl generation under UV irradiation. A 3-fold improvement in response compared to conventional pneumatic nebulization (PN) was achieved using 2.5% w w-1 ethanol and 400 mg kg-1 CuAc2, with a 2 mL min-1 sample flow rate (about 23 s of sample irradiation time). This optimized PVG ICP-MS/MS system yielded a blank-limited limit of detection (LOD) of 0.007 mg kg-1, 6-fold better than that obtained using PN ICP-MS/MS. Accounting for a needed 40-fold dilution of the sample, a practical LOD of 0.26 mg kg-1 was achieved for fuel ethanol samples. The proposed PVG ICP-MS/MS method represents a sensitive and accurate alternative for routine monitoring of inorganic Cl- in fuel ethanol with sufficient LOD to comply with levels required by regulatory agencies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Efficient Photochemical Vapor Generation of Bismuth and Selenium in Low Concentration of Isopropyl Alcohol and Organic Acid Medium.Analytical chemistry · 2026
- Determination of rhenium in sea and fresh water samples by coupling cadmium and iron ion-assisted photochemical vapor generation to inductively coupled plasma mass spectrometrySpectrochimica Acta Part B Atomic Spectroscopy · 2026
- Sample-Handling Bias and Direct ICP-MS of Ultratrace Metals in Semiconductor-Grade Isopropyl AlcoholACS Omega · 2026
- Sustainable ionic liquid-assisted cloud point extraction for enrichment of trace copper(II) in water and food samples prior to spectrophotometric determinationScientific Reports · 2026
- Investigation of the CL-resin® properties for a sulfur-free content molecule protocolAnalytica Chimica Acta · 2026
- Digital Colorimetric Approach for Rapid Determination of Acetaldehyde in Pisco Head During DistillationChemosensors · 2026