A practical HPLC-UV method for the simultaneous screening of decabromodiphenyl ethane and its debromination products in environmental matrices.
Wenrui Zhang, Yongchao Lei, Yanlong Wang, Peng Liang, Haifeng Zhou, Junhui Chen
College of Safety and Environmental Engineering, Shandong University of Science and Technology, Qingdao, Shandong 266590, P.R. China. wenrui.mao@163.com. · College of Chemical and Biological Engineering, Shandong University of Science and Technology, Qingdao, Shandong 266590, P.R. China.
Key points
From the paper's conclusion- The main advantage of this method is its simplicity, providing a practical screening tool for routine environmental monitoring laboratories.
Abstract
A high-efficiency, high-performance liquid chromatography-ultraviolet detection (HPLC-UV) method was developed for the simultaneous determination of decabromodiphenylethane (DBDPE) and its eight debromination products (one nona-, four octa-, two hepta-, and one hexa-brominated compounds) in soil and water samples. Key steps in the sample preparation process, such as solid-phase extraction and liquid-liquid extraction, were systematically optimized to enhance extraction efficiency and purification. This resulted in the average recovery rate of soil and water increasing by 40% and 20%, respectively, compared with that before optimization, meeting the requirements for trace organic pollutant analysis. Using an Agilent Zorbax Eclipse PAH column (2.1 mm × 100 mm × 1.8 µm) with a mobile phase of water containing 5 mM ammonium acetate aqueous solution and acetonitrile, gradient elution (flow rate of 0.4-0.7 mL min-1) was employed. At a UV detection wavelength of 230 nm, baseline separation of all target compounds was achieved. The method demonstrated good linearity across a wide concentration range (R2 > 0.992). The method's limits of detection (LOD) and quantification (LOQ) for soil matrices ranged from 0.013-3.093 ng g-1 dry weight (dw) and 0.042-10.310 ng g-1 dw, respectively. For water matrices, the LOD and LOQ ranged from 0.250-61.860 ng L-1 and 0.833-206.200 ng L-1, respectively. The relative standard deviation (RSD) ranged from 0.27% to 1.59%, indicating high precision. The main advantage of this method is its simplicity, providing a practical screening tool for routine environmental monitoring laboratories. It can complement high-resolution mass spectrometry techniques and is suitable for large-scale environmental surveys and preliminary risk assessments of DBDPE and its transformation products.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A natural deep eutectic solvent‑based liquid‑liquid microextraction for the determination of bisphenols in mineral and river water samplesTalanta · 2026
- Modified dispersive solid-phase extraction of benzophenones and parabens from water samples using nutshell-derived biochars: development, validation and greenness assessment.Journal of chromatography. A · 2026
- Fabric Phase Sorptive Extraction Prior to HPLC-DAD Determination of Monomers Released from Dental Resin Composites in Dental Wastewater.Molecules (Basel, Switzerland) · 2026
- Hydrophobic natural deep eutectic solvent-based DLLME for the green HPLC determination of paraben and alcohol preservatives in water samples.Talanta · 2026
- Characterization of radical-mediated degradation of phthalate esters in natural waters using carbon isotope fractionation.Water research · 2026
- Agricultural Waste-derived bio-sorbents used for the analysis of UV filters in sea water samples: An in-depth comparison with commercial sorbents.Journal of chromatography. A · 2026