The Analyst

Sensitive fluorescent biosensors based on a cascade signal amplification strategy and a stimuli-responsive hydrogel for the detection of the p53 gene.

Xiaoya Wu, Qiuhang Chen, Jianjun Zheng, Yuling Gao, Yingjuan Cao, Zhixin Li, Zhiqin Chen

Department of Gynecology, Fuzhou University Affiliated Provincial Hospital, Fuzhou, Fujian, 350116, China. zhiqinch@163.com. · Institute for Advanced Study, Research Center for Differentiation and Development of TCM Basic Theory, Jiangxi University of Chinese Medicine, Nanchang, Jiangxi, 330004, China. zhixinli@jxutcm.edu.cn.

Key points

From the paper's conclusion
  • Herein, a novel fluorescent biosensor based on a Cas12a/alkaline phosphatase (ALP) cascade signal amplification strategy and a stimuli-responsive DNA hydrogel was constructed for sensitive quantification of the p53 gene.

Abstract

As a key tumor suppressor gene, the mutation and abnormal expression of p53 are closely correlated with tumor occurrence and progression, making p53 an important biomarker for early tumor diagnosis. Herein, a novel fluorescent biosensor based on a Cas12a/alkaline phosphatase (ALP) cascade signal amplification strategy and a stimuli-responsive DNA hydrogel was constructed for sensitive quantification of the p53 gene. Highly stable carbon dot/silica (CD/SiO2) composites were adopted as excellent fluorescent signal-sensing elements with outstanding optical stability in complex environments. An ALP-encapsulated hyaluronic acid (HA)-DNA hydrogel was prepared as a stimuli-responsive recognition element. Specific binding of the target p53 gene activates the trans-cleavage activity of CRISPR/Cas12a, which cleaves the HA-DNA hydrogel structure and triggers the release of ALP. The released ALP further catalyzes the hydrolysis of the p-nitrophenyl phosphate (PNPP) substrate to generate p-nitrophenol (PNP). The generated PNP quenches the fluorescence of CD/SiO2 composites through the inner filter effect (IFE), and the fluorescence quenching value is positively correlated with the p53 gene concentration. The biosensor exhibited a favorable linear detection range of 1 pM-100 nM with a low detection limit of 0.074 pM. The proposed strategy eliminates cumbersome pre-amplification procedures for nucleic acids, provides a simple, sensitive and reliable new approach for p53 gene detection in complex biological samples, and exhibits great potential for early tumor auxiliary diagnosis and clinical biological analysis.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers