Modulation of aggregation-induced emission through substituent-driven amide-imidic acid tautomerism in a phenoxybenzohydrazide-based fluorescent probe for selective Fe3+ detection.
Mohd Arbaz Tyagi, Jadrichcha Nanda Saikia, Nitish Kumar Singh, Jehova Jire L Hmar, Jugal Bori
Department of Chemistry, Netaji Subhas University of Technology, New Delhi, 110078, India. jugalchmbori@gmail.com. · Department of Physics, Netaji Subhas University of Technology, New Delhi, 110078, India.
Key points
From the paper's conclusion- These research findings highlight the effectiveness of AIEgen L as a suitable fluorescent platform for the highly selective and sensitive detection of Fe3+ metal ions.
Abstract
A novel aggregation-induced emission (AIE) phenoxybenzohydrazide-based probe, namely, N'-[(4-(dimethylamino)phenyl)methylidene]-2-phenoxybenzohydrazide (L), was designed and synthesized. The probe exhibited strong AIE behavior in aqueous environments, attributed to the hydrogen bonding between the amide nitrogen atom and water molecules. This substituent-driven hydrogen-bonding interaction favours the amide-imidic acid tautomerism and the consequent restriction of intramolecular motion (RIM), leading to an efficient fluorescence enhancement upon aggregation. In contrast, a structurally related analogue, N'-(4-chloro-2-hydroxybenzylidene)-2-phenoxybenzohydrazide (L'), containing a different substituent at the imine carbon center, failed to exhibit AIE characteristics, highlighting the crucial role of electronic substituent effects in regulating hydrogen-bonding-assisted amide-imidic acid equilibrium and aggregation behavior. The probe L exhibits a highly sensitive and selective fluorescence quenching response towards Fe3+ metal ions, with a detection limit of 2.629 µM. The strong response of the probe, even in the presence of competing ions, proves its capability to be used as a reliable tool for environmental monitoring. The coordination modes between Fe3+ and L were confirmed by Job's plot, mass spectrometry, FT-IR spectroscopy, and DFT studies. The practical applicability of L was assessed via real-time estimation of Fe3+ ions in tap, river, and pond water samples. These research findings highlight the effectiveness of AIEgen L as a suitable fluorescent platform for the highly selective and sensitive detection of Fe3+ metal ions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Aggregation induced emission based fluorescent and colorimetric sensor for selective detection of Fe2+: experimental and computational insights with real-time applications.RSC advances · 2026
- "Turn-on" fluorescence sensor for Sc3+ based on Schiff-based tetraphenylethylene.RSC advances · 2026
- Design and Synthesis of Dual Fluorophore for Detection of Fe3+ and Hg2+ in Aqueous Solution Through Fluorescence "Turn-Off".Luminescence : the journal of biological and chemical luminescence · 2026
- Heteroligand Metal‐Organic Frameworks With Low Background for Ratiometric Luminescent “Turn on” Sensing of Multiple TargetsAdvanced Functional Materials · 2026
- Amide–Imine‐Linked Naphthalene‐ p ‐cresol System for Selective Fluorescence Recognition of IodideChemistrySelect · 2026
- Lights, Molecule, Action: 3-(Diarylmethylene)isobenzofuranones as Heteroatom-Containing, Tunable Aggregation-Induced Emission Luminogens.Organic letters · 2026