科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ The Analyst2026-09-01

A smartphone-integrated colorimetric sensor array based on chiral carbon dot nanozymes for rapid biothiol discrimination.

Siyu Zhou, Xinbo Zhou, Daohong Cheng, Tianyu Wei, Xingyi Ma, Yu Zhao, Guoying Sun, Wei Zhang, Chunhuan Jiang

原始摘要(英文原文)· Original abstract
The discrimination of structurally similar biothiols remains a critical challenge in clinical diagnostics, as conventional nanozyme-based sensor arrays often suffer from limited signal diversity and poor discriminative ability. To address this, a colorimetric sensor array using two rationally designed chiral carbon dots (CDs) was constructed. The role of chirality was primarily reflected in regulating the catalytic heterogeneity and enriching the multi-channel response diversity rather than direct enantioselective recognition. The two chiral CDs possess markedly distinct oxidase-like and laccase-like activities. This disparity in catalytic activity effectively doubles the number of response channels, thereby enriching the cross-reactive signal patterns. The CDs catalyzed the oxidation of three chromogenic substrates, namely 3,3',5,5'-tetramethylbenzidine (TMB), 2,2'-azinobis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS), and the 4-aminoantipyrine/2,4-dichlorophenol (4-AP/2,4-DP) coupling system in the absence of H2O2, producing distinct colorimetric responses. The addition of thiols elicits a differential inhibition of this activity in a degree-dependent manner, thereby inducing characteristic changes in the colorimetric readout. The developed array enabled accurate simultaneous identification and quantitative analysis of four thiols, including glutathione (GSH), L-cysteine (Cys), homocysteine (Hcy), and thioglycolic acid (TGA), by extracting RGB values using a smartphone color picker app and combining them with principal component analysis (PCA), hierarchical cluster analysis (HCA), and supervised machine learning. The k-nearest neighbor (KNN), support vector machine (SVM), and random forest (RF) classifiers achieved overall classification accuracies ranging from 95.83% to 97.22%, which further confirmed the robustness and reliability of the proposed sensing strategy. PCA score plots showed well-separated clusters for all analytes over the concentration range of 1-100 μM, while HCA further confirmed 100% classification accuracy. Furthermore, the first principal component (PC1) exhibited good linear correlation with GSH and TGA concentrations in a wide linear range of 1-50 μM, and the detection limit for all thiols was 1 μM. Successful application in serum and urine samples highlights its potential for smartphone-based clinical disease diagnosis.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

A smartphone-integrated colorimetric sensor array based on chiral carbon dot nanozymes for rapid biothiol discrimination. — 科研速览 Science Skim