Lab on a chip

Novel 3D-printed microfluidic chip for automated real-time multi-route in vivo nanoplastics toxicity testing.

Preyojon Dey, Terence M Bradley, Alicia Boymelgreen

Department of Mechanical and Materials Engineering, Florida International University, 10555 W Flagler St, Miami, FL, 33174, USA. pdey004@fiu.edu. · Department of Fisheries, Animal and Veterinary Science, University of Rhode Island, Kingston, RI 02881, USA.

Preclinical

Key points

From the paper's conclusion
  • In this study, we present a fully 3D-printed, automated microfluidic chip designed for multi-route in vivo nanotoxicity testing, which addresses the limitations of conventional methods by offering automated and dynamic exposure conditions alongside real-time monitoring through fluorescence imaging and oxygen sensing.

Abstract

Plastics are one of the most pervasive pollutants in marine environments, with smaller-sized plastics, such as nanoplastics (NPLs), posing significant but understudied threats to marine organisms. Traditional bulk and end-point testing methods offer limited capability for real-time, in situ assessment of nanotoxicity. In this study, we present a fully 3D-printed, automated microfluidic chip designed for multi-route in vivo nanotoxicity testing, which addresses the limitations of conventional methods by offering automated and dynamic exposure conditions alongside real-time monitoring through fluorescence imaging and oxygen sensing. Additionally, this platform simplifies the fabrication process, avoiding the time-consuming soft-lithography typically used for microfluidic chips and increasing accessibility to users without specialized expertise. As a proof of concept, the chip was used to assess nanotoxicity in model marine organisms across different trophic levels: Artemia franciscana (instar II and III stages) and a mixture of five microalgae. Polystyrene nanoplastics, one of the most prevalent plastics in marine environments, were used as the model NPLs and tested in two exposure routes: waterborne and foodborne. The results revealed distinct uptake dynamics; in Artemia, NPL-associated fluorescence initially increased and subsequently declined during waterborne exposure, whereas it continued to increase over the measured period during foodborne exposure. Oxygen-consumption responses varied by organism and exposure route: waterborne exposure produced a higher trend in Artemia and a significant increase in algae, whereas foodborne exposure produced a response comparable to its control. Together, continuous oxygen sensing and fluorescence imaging demonstrated the capability of the chip to monitor complementary physiological and NPL-uptake responses under multiple exposure routes in real time.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers