Experimental limitations introduced during cluster analysis in super-resolution microscopy due to the choice of labeling methods and fluorophores.
Kashish Jain, Valerie M Weaver, Pakorn Kanchanawong, Rishita Changede
Mechanobiology Institute, National University of Singapore, Singapore, Singapore. · Department of Surgery, University of California, San Francisco, CA USA.
Key points
From the paper's conclusion- In addition, we highlight other considerations for SMLM, including the clonality of the antibody, the number of fluorophores per antibody, steric hindrance to antibody binding, stochastic blinking of the fluorophore, and how to measure their effects to obtain a more accurate measure of the protein clusters or complexes.
Abstract
Advances in super-resolution fluorescence microscopy, particularly single-molecule localization microscopy (SMLM) techniques such as Photoactivated Localization Microscopy (PALM) and direct Stochastic Optical Reconstruction Microscopy (dSTORM), have enabled the precise visualization and quantification of individual protein molecules and the higher-order complexes formed. However, the relative accuracy and limitations of labeling and imaging parameters in quantifying diffraction-limited protein nanoclusters remain poorly characterized. Using well-characterized 2D focal adhesion kinase (FAK) clusters as a benchmark, we combined Monte Carlo simulations and experiments to assess labeling-induced errors. Antibody-based dSTORM exhibited up to ~42% quantification error relative to PALM, which decreased with smaller probes or monovalent nanobodies. In addition, we highlight other considerations for SMLM, including the clonality of the antibody, the number of fluorophores per antibody, steric hindrance to antibody binding, stochastic blinking of the fluorophore, and how to measure their effects to obtain a more accurate measure of the protein clusters or complexes. By systematically quantifying the contribution of linkage error to nanocluster size quantification, our study establishes a baseline for comparing its impact across the SMLM methods, which is critical for translating molecular localization into mechanistic biological insight.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Protein Nanocages as Tunable Stoichiometric Benchmarks for Quantitative SMLM.Molecular biology of the cell · 2026
- MaCADEMIA: a software toolbox for single-molecule fluorescence image quantificationbioRxiv · 2026
- Stoichiometrically Defined Antibody–DNA Conjugates for Quantitative Super-Resolution ImagingNano Letters · 2026
- direct Stochastic Optical Reconstruction Microscopy to Determine the Oligomeric State of Proteins on the Plasma Membrane and Their Accessibility for Immunotherapeutic Antibodies.Bio-protocol · 2026
- Toward Accurate Molecular Counting in EC-STORM via Reversible Stochastic Dye Switching.Nano letters · 2026
- Quantitative In-Cell Localization Microscopy: From Single-Molecule Localizations to Mechanistic Inference.Chemical & biomedical imaging · 2026