External validation of an image-only ultrasound model for delivery-date prediction in four Chilean public hospitals
Rodrigo Alliende-Ferrada, Ignacia Inostroza, Jocelyn Stern, Cristobal Pérez-Cotapos, Andrés Ruz
Hospital Santiago Oriente - Dr. Luis Tisne Brousse · Hospital Barros Luco-Trudeau
Key points
From the paper's conclusion- We externally validated a commercial image-only ultrasound deep-learning model for delivery-date prediction, applied unmodified to 64,235 frames from 3788 examinations of 2550 pregnancies (34% migrant) at four Chilean public hospitals.
Abstract
Abstract Accurate delivery-date estimation underpins obstetric care, yet conventional dating performs worst where it is most needed: late-presenting pregnancies without reliable early ultrasound or menstrual history, common in public-sector and migrant populations. We report an independent, multicentre external validation of a prospectively deployed, image-only ultrasound artificial-intelligence (AI) system that predicts days to delivery from standard ultrasound frames alone—without gestational age, biometry, demographics, annotations, or any dating input. Across 3,788 singleton studies from 2,550 pregnancies at four Chilean public hospitals, the AI predicted the delivery date with a mean absolute error (MAE) of 6.9 days (95% confidence interval [CI] 6.7–7.0). Critically, its accuracy was undiminished where conventional dating is structurally weakest: in pregnancies lacking reliable first-trimester dating the AI achieved an MAE of 6.4 days, whereas estimation from the established due date deteriorated to 13.2 days. The model’s high-coverage prediction intervals were well calibrated (96.5% empirical coverage of the approximately 94% interval), supporting a calibrated delivery-date range rather than a single date. Head-to-head within the same studies, the image-only estimate was more accurate than the due date as used in practice in 69% of pregnancies; prespecified sensitivity analyses showed that part of this margin reflects correction of a systematic, population-specific bias in the 280-day convention, with a smaller residual advantage in dispersion. This dating-independent, calibrated estimate could narrow a persistent equity gap for the patients whom conventional dating serves least well.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development and external validation of deep learning models for spontaneous preterm birth prediction from mid-trimester cervical ultrasoundScientific Reports · 2026
- Dynamic prediction of preterm birth and gestational age at delivery based on longitudinal electronic health records.NPJ digital medicine · 2026
- Predicting the risk of preterm birth with machine learning and electronic health records in ChinaBMC Medical Informatics and Decision Making · 2025
- Privacy-preserving, low-annotation pregnancy status classification from obstetric ultrasound reports using on-premises small language modelsScientific Reports · 2026
- Machine Learning Estimation of Gestational Age at Delivery Using Linked Mother-Infant Electronic Health Records Across Two Health Systems.Pharmacoepidemiology and drug safety · 2026
- Development and validation of a deep learning model for predicting small-for-gestational-age birth using routine mid-trimester ultrasound.Frontiers in medicine · 2026