Grounded report generation for enhancing ophthalmic ultrasound interpretation using Vision-Language Segmentation models
Kai Jin, Qixuan Sun, Daohuan Kang, Ziyao Luo, Tao Yu, Wenzheng Han, Yi Zhang, Meng Wang,
Zhejiang Technical Institute of Economics · Zhejiang University
Key points
From the paper's conclusion- Overall diagnostic accuracy was 90.59% in internal and 71.87% in external test sets.
Abstract
Accurate interpretation of ophthalmic ultrasound is crucial for diagnosing eye conditions but remains time-consuming and requires significant expertise. With the increasing volume of ultrasound data, there is a need for Artificial Intelligence (AI) systems capable of efficiently analyzing images and generating reports. Traditional AI models for report generation cannot simultaneously identify lesions and lack interpretability. This study proposes the Vision-Language Segmentation (VLS) model, combining Vision-Language Model (VLM) with the Segment Anything Model (SAM) to improve interpretability in ophthalmic ultrasound imaging. Using data from three hospitals, totaling 64,098 images and 21,355 reports, the VLS model achieved a BLEU4 score of 66.37 in internal test set, and 85.36 and 73.77 in external test sets. The model achieved a mean dice coefficient of 59.6% in internal test set, and dice coefficients of 50.2% and 51.5% with specificity values of 97.8% and 97.7% in external test sets, respectively. Overall diagnostic accuracy was 90.59% in internal and 71.87% in external test sets. A cost-effectiveness analysis demonstrated a 30-fold reduction in report costs, from $39 per report by senior ophthalmologists to $1.3 for VLS. This approach enhances diagnostic accuracy, reduces manual effort, and accelerates workflows, offering a promising solution for ophthalmic ultrasound interpretation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Vision-Language Model as a 'Zero-Shot' Assistant for Evaluating Condylar Osseous Changes in Cone-beam Computed Tomography.International dental journal · 2026
- Beyond Report Imitation: Clinically Aware Multi-Image Ultrasound Report Generation from Visible EvidencearXiv · 2026
- A multitask framework for automated multi-frame right upper quadrant ultrasound interpretation and clinical decision support.Nature communications · 2026
- Large language models for ophthalmic examination understanding: from information extraction to clinical decision support.Frontiers in medicine · 2026
- Image-Based Diagnosis of Oral Lesions: Performance of a Vision-Language Model versus Human Clinicians.Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2026
- OphthoACR (Ophthalmology Automated Chart Review): An AI-Powered Tool for Complete Automation of Ophthalmology Chart Reviews and Cohort Data AnalysisTranslational Vision Science & Technology · 2025