First-in-human feasibility study of a portable low-field pulsed-gradient-free MR device in acute stroke
James L. Barker, Yu-Chieh Tzeng, Paul D. Teal, Dion Thomas, Leonid Churilov, Amy McDonald, Tyson Moed, Samantha Rivet,
Key points
From the paper's conclusion- We conducted the first-in-human evaluation of a novel portable low-field 0.1 T pulsed-gradient-free magnetic resonance (MR) device (~ 100 kg) that acquires regional MR biomarkers for bedside stroke assessment.
Abstract
We conducted the first-in-human evaluation of a novel portable low-field 0.1 T pulsed-gradient-free magnetic resonance (MR) device (~ 100 kg) that acquires regional MR biomarkers for bedside stroke assessment. We aimed to evaluate its safety, tolerability and feasibility in acute stroke. This single-centre non-randomised observational cohort study prospectively recruited healthy controls and consecutive stroke patients within 72-h of hospital presentation. Participants underwent conventional 1.5–3 T MRI and two consecutive device scans (DWI, T2). The primary outcomes were feasibility with the proportion of scans where an interpretable signal-to-noise ratio (SNR) was obtained, safety, and tolerability via survey. Forty of forty-nine participants with acute stroke (34 ischemic and 6 hemorrhagic) had successful scans; median age 71 (years[IQR 58.5–76.5]); median NIHSS 4.5 [IQR 2.0–12.0]) and 20 healthy controls were enrolled. No device-related safety concerns were identified, and the scanner was generally well tolerated. SNR ≥ 3 for algorithm-based analysis were obtained in 36/40 (90.0%) stroke participants and 12/40 (30.0%) achieved the higher threshold for heatmap visualisation (SNR ≥ 12). This first-in-human study demonstrates the safety, tolerability, and technical feasibility of operating the device within an inpatient stroke workflow and generate interpretable MR-derived signals in most patients. These findings justify larger prospective studies to evaluate diagnostic performance and clinical implementation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Low-Field and Portable MRI for Acute Ischemic Stroke: A Systematic Review.Brain sciences · 2026
- Portable ultra-low field MRI in neurocritical care and intensive care units: A systematic review of diagnostic performance and feasibility.Emergency radiology · 2026
- Ultra-low-field portable MRI in neuroscience: Current status and future directionsJournal of Neuroradiology · 2026
- A Reference System for Open Source Portable Low-Field MRIarXiv · 2026
- A compact portable MRI system for in-situ imaging and diffusion measurements.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2026
- Portable ultra-low-field MRI in Africa: an access technology in search of an evidence base built without a safety net.European journal of radiology · 2026