Inter-rater reliability, agreement and measurement error of CT-based three-dimensional proximal femoral morphometry in dry cadaveric femora
Mohammad Imad Awad Ghannam, Nur Arfian, Arif Faisal, Yudha Mathan Sakti
Key points
From the paper's conclusion- We quantified the inter-rater reliability, agreement and measurement error of ten proximal femoral parameters measured independently by two blinded raters on 3D models of 20 adult dry cadaveric femora.
Abstract
Computed tomography (CT)-based three-dimensional (3D) morphometry is widely used to describe the proximal femur, yet the measurement properties of individual parameters are rarely reported. We quantified the inter-rater reliability, agreement and measurement error of ten proximal femoral parameters measured independently by two blinded raters on 3D models of 20 adult dry cadaveric femora. Reliability was quantified with the intraclass correlation coefficient [ICC(2,1)], measurement error with the standard error of measurement (SEM) and minimal detectable change, and agreement and systematic bias with Bland–Altman analysis and paired t-tests. Six linear dimensions and the distal canal diameter (FCD2) showed excellent reliability (ICC 0.936–0.995; SEM 0.32–1.31 mm). The neck-shaft angle showed good reliability (ICC 0.778), and femoral anteversion (FAA; ICC 0.676) and the proximal canal diameter (FCD1; ICC 0.705) moderate reliability. Significant systematic differences between raters occurred for FAA (4.55°), FCD1 (1.13 mm) and FCD2 (0.49 mm), the latter despite excellent reliability. FAA had the largest measurement error (SEM 4.90°; limits of agreement − 9.0° to + 18.2°). These results describe agreement between two raters under one protocol; they do not establish anatomical accuracy, which requires comparison with a reference standard.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Establishment and Evaluation of the Reliability of Computed Tomography-Based Femoral Joint Reference Angles in Normal French Bulldog Limbs.Veterinary and comparative orthopaedics and traumatology : V.C.O.T · 2026
- EP4.11 Accurate CT Segmentation and Reliable 3D Morphometric Measurements to Support Clinical Interpretation in FAIJournal of Hip Preservation Surgery · 2026
- EP4.10 Accuracy of Semi-Automated 3D CT Hip Measurement for Femoroacetabular Impingement: Validation Against Surgeon and Engineering Reference StandardsJournal of Hip Preservation Surgery · 2026
- TP4.2 Beyond 2D Radiographs: Prospective Quantitative 3D CT Assessment of Femoral Head Coverage Influences Planning of Periacetabular Osteotomy in Developmental Dysplasia of the HipJournal of Hip Preservation Surgery · 2026
- Reliability and measurement error of hip abductor muscle strength using a hand-held dynamometer in healthy adults.Journal of physical therapy science · 2026
- Exploring the Relationship Between Femoral Neck Torsion Angle and Anteversion Angle Through Three-Dimensional Reconstruction in a Fixed Coordinate System.International journal of general medicine · 2026