Scientific ReportsOpen accessPerfusion

Tumor perfusion shows substantial temporal dynamics in super-resolution ultrasound measurements across 3-h intervals

Alexandra Raab, Jasmin Baier, Céline Porte, Thomas Lisson, Pálma Emese Inczeffy, Rahaf Mihyar, Andreas Schuppert, Renée Michèle Girbig,

Universitätsklinikum Aachen · Ruhr University Bochum

Preclinical

Key points

From the paper's conclusion
  • These findings demonstrate that ULM-derived tumor perfusion parameters can vary substantially between measurements acquired at 3-h intervals and highlight the importance of temporal sampling when interpreting perfusion-sensitive imaging readouts.

Abstract

Abstract Tumor perfusion is highly heterogeneous due to the abnormal structure and function of the tumor-associated vasculature. While spatial heterogeneity is well recognized, variability over short time intervals remains less well characterized. Here, motion model ultrasound localization microscopy (ULM) was used to assess tumor microvascular parameters in two breast cancer xenograft models, MCF-7 (ER+/PR+) and BCSC1 (patient-derived triple-negative breast cancer model). Experiments were conducted in female BALB/cAnNRj-nu and NOD/SCID mice aged 6–8 weeks. ULM was performed using focused line-by-line nonlinear contrast imaging at a frame rate of 10 fps. Tumors were imaged longitudinally at identical positions over 9 h, with repeated acquisitions every 3 h following intravenous microbubble injections. Significant time effects were detected for mean track length and mean track-wise velocity range, while mean flow velocity and vessel tortuosity showed non-significant temporal trends. The remaining parameters showed no significant effects of time, tumor model, or interaction between time and model. Nevertheless, individual tumors showed substantial variability between measurement time points, most prominently in vessel coverage and distance to the closest track. These findings demonstrate that ULM-derived tumor perfusion parameters can vary substantially between measurements acquired at 3-h intervals and highlight the importance of temporal sampling when interpreting perfusion-sensitive imaging readouts.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers