Harm from indoor air contaminants in an office building
Giobertti Morantes, Chiara Nomellini, Irene Lara-Ibeas, Giulia Torriani, Francesco Babich
Key points
From the paper's conclusion- This study applies benchmark comparison (HQ), regulated harm (RH), and disability-adjusted life-year (DALY)-based harm assessment to measured indoor air contaminants in a monitored public office building in Bolzano, Italy.
Abstract
Indoor air quality in offices is usually interpreted through benchmark exceedance, although exceedance alone does not quantify health burden across a multi-contaminant mixture. This study applies benchmark comparison (HQ), regulated harm (RH), and disability-adjusted life-year (DALY)-based harm assessment to measured indoor air contaminants in a monitored public office building in Bolzano, Italy. In the primary benchmark assessment, propanal was the only contaminant with HQ > 1, while benchmark choice altered the ordering of contaminants below the exceedance threshold. When measured concentrations were translated into DALY-based harm, PM 2.5 , formaldehyde, and derived PM 10–2.5 were identified as prospective contaminants of concern within the quantified set and together accounted for 99.3% of mean total harm among 15 contaminants with available harm inputs. Benchmark comparison, regulated harm, and DALY-based harm provided complementary interpretations of the monitored mixture. HQ quantified proximity to selected health-based benchmarks, RH the model-based harm implied at those benchmark concentrations, and DALY-based harm the model-based impact at the measured concentrations. Their joint use links benchmark screening with health-based prioritisation of site-specific office measurements.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Organic Contaminants of Emerging Concern (OCECs) in Indoor Air: A Perspective on Global Distribution and Hazard Burden.Environmental science & technology · 2026
- Integrated Assessment of Indoor Air Pollution and Associated Health Risks in a Hemodialysis UnitIndoor Air · 2026
- Harmonizing indoor air quality standards across Europe: A comparative analysis framework for building material regulations and public health protectionBuilding and Environment · 2025
- Health-related interpretation of human biomonitoring results - new and updated human biomonitoring guidance values from PARC and HBM4EU.International journal of hygiene and environmental health · 2026
- Measurements of Hazardous Air Pollutants in Communities Necessitate Review of Air Quality and Exposure Metrics.Environmental science & technology letters · 2026
- Desk‐Level CO 2 Sensing for Monitoring Occupancy and Indoor Environmental QualityIndoor Air · 2026