Parameter optimization of a porous curved guide wall for inflow improvement in a 90° sharp-bend pumping station
Yun-wei Li, Bin Xi, Wen-tong Wang, Hong-jun Liu, Wei Chen, Jia-wen Lu
Key points
From the paper's conclusion- This study confirms that rational parameter configuration of the porous curved guide wall can successfully regulate flow patterns in complex bend intake systems and enhance unit inflow quality.
Abstract
To address the forebay flow disorder and asymmetric unit inflow induced by a 90° sharp-bend approach channel, a multi-objective evaluation system was established combining physical modeling and numerical simulation. Parameter optimization of the porous curved guide wall was conducted via CFD, orthogonal experiments, and the Entropy-weight TOPSIS method. The results show that the optimized scheme effectively eliminated the large-scale recirculation zone induced by the 90° bend, reducing its volume by 62.32%. The axial velocity uniformity in the forebay was substantially improved, with a maximum increase of 103.46%. Furthermore, the velocity-weighted average flow deviation angle of the Unit 1 intake conduit decreased from 13.36° to 5.26°, achieving a reduction of 60.63%. This study confirms that rational parameter configuration of the porous curved guide wall can successfully regulate flow patterns in complex bend intake systems and enhance unit inflow quality. The optimized scheme yields remarkable effects, providing a reference for the design and management of similar engineering projects.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hydraulic test study on the pressure slope section at the inlet of the outlet tunnel of shaft spillwayJournal of Physics: Conference Series · 2026
- Effect of Sidewall Corner Modification on the Flow Pattern in the Forebay of a Side-Inlet Pumping StationWater · 2026
- Improving flow measurement accuracy in pumping stations based on flow deviation angle correctionJournal of Physics: Conference Series · 2026
- A pseudo three-dimensional topology optimization aerodynamic resistance reduction method for industrial flow components.Communications engineering · 2026
- Numerical Simulation Analysis and Structural Optimization of a Gas Jet PumpProcesses · 2026
- Numerical Investigation of Gas-Liquid Multiphase Flow Characteristics and Nozzle Structure Optimization for a Multi-Hole Oxygen Lance in a Vanadium Extraction Converter.Materials (Basel, Switzerland) · 2026