Scientific Reports

Deep learning-based computer-aided detection of cerebral microbleeds achieves high sensitivity with a low false-positive rate in a confirmatory clinical trial

Hyug-Gi Kim, Eunwoo Lee, Jeong Taek Yoon, Inkeon Yeo, Jin San Lee, Minho Lee, Sang-Yeong Jo, Danbi Song,

Trial · n=456

Key points

From the paper's conclusion
  • Neurophet SCALE MRI demonstrated high sensitivity and specificity along with a low false-positive rate, supporting its potential clinical utility.

Abstract

Cerebral microbleeds (CMBs) are small, focal brain lesions recognized as critical biomarkers of cerebrovascular disease and cognitive decline. Despite advances in MRI technology, detecting CMBs remains challenging, highlighting the need for automated tools. This study aimed to evaluate the standalone performance of Neurophet SCALE MRI for automated CMB detection. The model was trained on 201 SWI and phase examinations. Neurophet SCALE MRI employs a two-stage deep learning pipeline with preprocessing steps, including reorientation, resampling, and data augmentation. In the first stage, CMB candidates are generated using a multiscale backbone and bidirectional convolutional Long Short-Term Memory. The second stage reduces false positives through a Squeeze-and-Excitation ResNet-based classifier and brain tissue segmentation. In this retrospective, single-center clinical trial, the model was tested on 457 MRI examinations. The primary endpoints were lesion-wise sensitivity (> 85.7%) and false positive rate (< 2.35 per patient). In addition, patient-wise and group-wise analyses were conducted. A total of 456 participants (224 CMB-positive, 232 CMB-negative) with 515 CMB lesions were included for the statistical analysis. The device exceeded all predefined performance criteria, demonstrating a lesion-wise sensitivity of 88.35% (95% CI: 86.61–90.17) and a false positive rate of 0.95 per patient (95% CI: 0.83–1.07). Patient-wise sensitivity and specificity were 1.0 (95% CI: 0.98–1.0) and 0.86 (95% CI: 0.81–0.90), respectively. For group-wise classification (0–4 vs. ≥5 CMBs), sensitivity and specificity were 0.91 (95% CI: 0.88–0.93) and 0.95 (95% CI: 0.74–1.0). Neurophet SCALE MRI demonstrated high sensitivity and specificity along with a low false-positive rate, supporting its potential clinical utility. Further validation by expert readers in a broader population is warranted.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Deep learning-based computer-aided detection of cerebral microbleeds achieves high sensitivity with a low false-positive rate in a confirmatory clinical trial — Science Skim