Simultaneous correction of spectral-line bending across multiple slits in a slit recombination hyperspectral imager with multiple viewing angles
Yanlin Niu, Long Wang, Jialun Zhang, Chao Lin, Zhenhua Ji, Yang Fu, Yuquan Zheng
Key points
From the paper's conclusion- This method provides a design reference for multi-angle hyperspectral imaging systems with low spectral-line bending and geometrically separated slit spectra.
Abstract
Simultaneous spectral-line bending correction is required for the central and off-axis slit channels of a multi-angle slit-recombination hyperspectral imager. This study develops a modeling and optimization method using an oppositely oriented dual-material prism group. The model describes spectral-line bending as a function of wavelength, slit channel, and position along the slit. A prism-group merit function guides material screening, and a system-level merit function incorporating distortion guides genetic-algorithm optimization of the prism parameters. Complete-system optimization and numerical evaluation are performed in Zemax for a three-slit design operating over 410–900 nm, using the H-QF3/D-ZLaF81-25 prism group as the sole dispersive element. For the evaluated wavelengths and field positions spanning 410–900 nm, the maximum optical spectral-resolution bandwidths, quantified by the full width at half maximum (FWHM) of the wavelength-domain line-spread function (LSF), are 9.35, 9.43, and 9.75 nm for the + 15°, 0°, and − 15° viewing channels, respectively, all below the 10-nm requirement. The ray-tracing results show that the three slit spectra are geometrically separated on the detector plane. The spectral-line bending and keystone distortion of all slit channels are less than 0.5 effective pixel in the spectral and spatial directions, respectively. At 650 and 900 nm, the sagittal and tangential optical modulation transfer function (MTF) values exceed 0.7 at 25 lp/mm for the plotted field points in all three slit channels. Relative to a reference with two upright prisms, the optimized design reduces the maximum absolute spectral-line bending to 0.0012–0.0024 mm, with an average reduction of approximately 94%. This method provides a design reference for multi-angle hyperspectral imaging systems with low spectral-line bending and geometrically separated slit spectra.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Lollipops for HARMONI: a sweet guide probe modelRAS Techniques and Instruments · 2026
- Method for meteorological optical range measurement traceability based on programmable spectral shaping.Optics express · 2026
- Robust reconstruction of images degraded by prism-induced non-uniform deflection in wide field variable resolution imaging via multi-channel structure guided fusion.Optics express · 2026
- High-accuracy synchronous distortion-compensated stereo phase measuring deflectometry with orthogonal geometric constraintsOptics Express · 2026
- Data-efficient linear hyperspectral imaging through risk-guided co-designarXiv · 2026
- Design and Demonstration of Compact and Lightweight Imaging Spectrometer Based on Schwarzschild Reflector Systems Using Commercial Off-the-Shelf OpticsSensors · 2025