A quantitative geophysical–geotechnical framework for slope stability analysis using electrical resistivity tomography
Widodo, Hermawan Panjaya, Simon Heru Prassetyo, Ganda Marihot Simangunsong, Ridho Kresna Wattimena, Agus Haris Widayat, Fatkhan, Taufiq Bin Nur,
Key points
From the paper's conclusion- These results demonstrate that electrical resistivity can provide spatially continuous, site-specific geotechnical information for preliminary slope stability assessment when calibrated and constrained by borehole and laboratory data.
Abstract
Slope instability constitutes a major constraint on infrastructure development in geologically complex and rapidly urbanizing regions such as West Java, Indonesia. Reliable slope stability analysis requires spatial characterization of subsurface mechanical parameters, including cohesion, internal friction angle, and bulk density. Conventional geotechnical investigations provide accurate point-scale data but are often constrained by high cost, limited spatial coverage, and logistical challenges. This study presents an integrated geoelectrical–geotechnical framework enabling the quantitative use of electrical resistivity for slope stability assessment. The investigation was conducted in the Padalarang District, West Bandung Regency, an area dominated by volcanic lithologies. Electrical Resistivity Tomography and Vertical Electrical Sounding were integrated with borehole logs, Standard Penetration Test data, and laboratory measurements to derive empirical correlations between resistivity and key geotechnical parameters. The results indicate a very strong correlation between electrical resistivity (ρ) and cohesion (R 2 = 0.8270), a strong correlation with bulk density (ρᵦ) (R 2 = 0.6860), and a weak correlation with internal friction angle (R 2 = 0.1780). The resistivity-derived parameters were incorporated into limit-equilibrium slope stability analysis under the specified groundwater condition. The representative resistivity-derived parameter model produced a Factor of Safety (FoS) of 2.60, while the final spatially integrated slope model yielded a minimum FoS of 1.23. These results demonstrate that electrical resistivity can provide spatially continuous, site-specific geotechnical information for preliminary slope stability assessment when calibrated and constrained by borehole and laboratory data.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Analysis of Landslide Slip Surfaces Using Geoelectrical Methods A Case Study in Cianjur, West Java, IndonesiaJournal of Physics: Conference Series · 2026
- Site specific geophysical-geotechnical integration: correlating ERT and SPT for subsurface characterisationJournal of Petroleum Exploration and Production Technology · 2026
- Characterizing landslide dynamics from time-lapse time domain induced polarization and ground-based imaging: a case study of the MontGombert landslide (French, Alps)arXiv · 2026
- Integrated Electrical Resistivity Tomography and Borehole Correlation for Characterizing Salt Formation Geometry and Groundwater Circulation at Slănic Prahova, RomaniaWater · 2026
- Multi-method geophysical characterization and failure mechanism of a rainfall-induced loess landslide constrained by borehole data: a case study in Zichang, Yan’anGeoenvironmental Disasters · 2026
- Integrated Geological and Geophysical Characterization of the 2024 Lernapat Landslide, Armenia: Slip-Surface Delineation and Stability AssessmentGeoHazards · 2026