A height-aware design framework for single-tuned mass dampers in seismic steel buildings
Mohamed M. Shabib, Hassan M. Farag, Yasser A. Khalifa, M. S. Zahran
Key points
From the paper's conclusion- This study presents a height-aware engineering design framework for roof-mounted single-tuned mass dampers (STMDs) in multi-story steel buildings.
Abstract
This study presents a height-aware engineering design framework for roof-mounted single-tuned mass dampers (STMDs) in multi-story steel buildings. Five three-dimensional steel models with 5, 10, 12, 15, and 20 stories were analyzed in ABAQUS/CAE under the Kobe and Loma Prieta earthquake records. A baseline assessment first applied the Sadek tuning procedure using a fixed 5% mass ratio to investigate the influence of building height. The resulting response trends were interpreted using natural periods, modal-mass participation, a higher-mode influence index, and a detuning indicator. The 12-story model yielded the largest baseline roof-displacement reductions, reaching 46.0% under Kobe and 21.0% under Loma Prieta, whereas the corresponding reductions for the 20-story model were 12.8% and 10.7%, respectively. A surrogate-based parametric design exploration was subsequently used to examine practical combinations of mass ratio, tuning ratio, and damping ratio within prescribed bounds. The surrogate exploration identified candidate parameter sets that substantially mitigated dynamic demands in low- and mid-rise structures; however, it failed to overcome the intrinsic modal-dispersion bottleneck in the 20-story frame. For that model, combining the STMD with shear walls or outer inverted-V bracing increased the roof-displacement reduction to 45.4–65.5%, depending on the earthquake record and lateral-resisting configuration. The proposed sequence height screening, parameter exploration, and hybrid-system assessment provide a structured design process for selecting the control strategy within the investigated building family. However, the control efficacy of standalone STMDs remains fundamentally limited in taller, flexible buildings due to higher-mode mass participation and nonlinear frequency detuning. The present findings are bound by the investigated prototype steel frames, uniform cross-sectional benchmark assumptions, fixed-base boundary conditions, and the selected ground motion records.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- High Mass Ratio Tuned Mass Dampers Obtained Through Building Superelevations for Seismic RetrofitThe Eurasia Proceedings of Science Technology Engineering and Mathematics · 2026
- Comparative FEM Analysis of Two Beam-Type TMD Sizing Methods Under Motor-Induced Vibrations in a Steel FrameJournal of Vibration Engineering & Technologies · 2026
- Comparative Experimental and Numerical Evaluation of Passive Damping in a Slender Steel FrameMachines · 2026
- Performance Analysis and Optimization of Distributed Tuned Mass Damping System for Tall Buildings Under Wind‐Induced Translational and Torsional Coupling ResponseThe Structural Design of Tall and Special Buildings · 2026
- Parameter Symmetrization and Seismic Response Redistribution in a Curved Ramp Bridge with Steel DampersSymmetry · 2026
- Multi‐Hazard Wind‐Seismic Vibration Mitigation of Tall Buildings Using Tuned Mass Damper Inerter (TMDI) and Structural Modification: Numerical Optimization and Experimental ValidationEarthquake Engineering & Structural Dynamics · 2026