Scientific Reports

A multi task deep learning framework for automated health condition prediction from retinal fundus images using hybrid attention and explainable AI

Ravi Kumar Tenali, Anitha Potnuri

Computational

Key points

From the paper's conclusion
  • This proposed framework could be considered for an additional potential step toward the future when it comes to multi-disease fundus screening with an interpretable single-model solution, if it is assessed and approved at an independent multi-centre level and by regulatory bodies.

Abstract

Although retinal fundus imaging is a non-invasive tool to assess systemic and fundus pathology, current deep learning algorithms are mostly single-task, lack clinical interpretability and are unable to handle acquisition variation between different domains. These constraints limit their clinical utility: when a patient comes to the clinic for fundus screening, they could also be diabetic, have glaucoma, AMD, and increased cardiovascular risk, with each disease having retinal vascular biomarkers that require a patient to be tested for in the clinic, which must be managed within a framework of common, interpretable, and generalizable models rather than a pipeline of independent models. To solve these problems, we suggest a multi-task deep learning network that simultaneously classifies DR severity (five-class), glaucoma likelihood (binary), AMD stage (four-class) and cardiovascular risk (binary) from a single retinal fundus image using a single forward pass. It adopts an EfficientNet-B4 convolutional backbone pretrained on the ImageNet dataset, a six-layer multi-head self-attention Transformer encoder (d_model = 512, h = 8), a novel dual-branch spatial-channel attention module that builds on, but significantly expands, the CBAM module, and four task-specific output heads that are optimized using the homoscedastic uncertainty-weighted multi-task loss following the formulation of Kendall et al. Per-task anatomical explanations are produced by back propagating the CNN backbone via Grad-CAM in the anatomical space. The proposed model was evaluated on EyePACS, APTOS 2019, Messidor-2 and RIM-ONE v3 and achieved an accuracy of 94.7%, AUC = 0.978, sensitivity = 93.2% and specificity = 95.8% while being statistically better than all single task models (DeLong test, p < 0.01, Bonferroni corrected). Under the reported experimental setting, the zero-shot cross-dataset evaluation achieves AUC ≥ 0.951, which is promising for its performance across datasets. Grad-CAM saliency maps are anatomically similar to established clinical grading criteria for each disease. The four task-specific heads share a single architecture and produce four outputs in one forward pass, but no individual patient in the training corpora had verified ground-truth labels for all four conditions simultaneously; the model is trained on partially labelled, multi-source data via a masked multi-task loss, and the cardiovascular output is an AVR-derived image-based surrogate rather than a validated clinical cardiovascular diagnosis. This proposed framework could be considered for an additional potential step toward the future when it comes to multi-disease fundus screening with an interpretable single-model solution, if it is assessed and approved at an independent multi-centre level and by regulatory bodies.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers