Fluorescence imaging enables multiscale profiling of therapeutic antibody delivery across entire surgical specimens
Hidenori Tanaka, Mabrooka Kazi, Carleigh R. Burns, Makenna Brown, Nicole Meeks, Shravan V. Gowrishankar, Jasmine M. Jain, Michael C. Topf,
Vanderbilt University
Key points
From the paper's conclusion- We aimed to validate macroscopic (21–337 μm/pixel) fluorescence measurements against microscopy (0.3 μm/pixel) and to characterize multi-scale heterogeneity of Pan800-derived fluorescence using a high-throughput, slide-free fluorescence imaging approach.
Abstract
Abstract Antibody delivery to solid tumors is often assumed to be uniform, yet this has not been systematically evaluated in human tissues. Optically labeled antibodies such as panitumumab-IRDye800CW (Pan800) remain detectable in FFPE specimens, enabling direct assessment of in vivo drug distribution. We aimed to validate macroscopic (21–337 μm/pixel) fluorescence measurements against microscopy (0.3 μm/pixel) and to characterize multi-scale heterogeneity of Pan800-derived fluorescence using a high-throughput, slide-free fluorescence imaging approach. A total of 946 FFPE blocks from seventeen patients who received systemic Pan800 were analyzed using near-infrared fluorescence imaging. Selected blocks were sectioned for fluorescence microscopy validation. Fluorescence intensities were compared between cancer-positive and -negative blocks, decalcified versus non-decalcified specimens, and across blocks within and between patients. Across resolutions (21–337 μm), maximum fluorescence intensity (FIₘₐₓ) discriminated cancer-positive from -negative blocks, while low-resolution scanning enabled rapid acquisition (~ 1 min/block). Macroscopic fluorescence signals correlated with microscopy at the section level (R 2 = 0.73), within patients (R 2 = 0.66), and across patients (R 2 = 0.66). Decalcification significantly reduced fluorescence at the block level (median FI max : 875 vs 287; P < 0.0001), and this reduction was confirmed in patient-level paired analyses when stratified by cancer status (P < 0.05). After excluding decalcified samples, FIₘₐₓ successfully differentiated cancer-positive from cancer-negative blocks (AUC = 0.78), with higher accuracy in lymph nodes than primary tumors. Marked intra- and inter-patient heterogeneity in Pan800-derived fluorescence was observed. Macroscopic fluorescence correlates with microscopic measurements and pathologically confirmed cancer presence, validating a high-throughput method for Pan800 distribution in clinical specimens. Signal heterogeneity precludes inference from single sections, supporting multi-block evaluation and a hierarchical workflow integrating screening with targeted microscopy. Clinical trial registration: NCT#04511078, first posted on 08/12/2020, https://clinicaltrials.gov/study/NCT04511078 ; NCT#05945875, first posted on 07/14/2023, https://clinicaltrials.gov/study/NCT05945875 .
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Large-scale quantitative assessment of tissue preparation and staining conditions for robust multiplexed imaging of FFPE tissue samples.Nature methods · 2026
- Computational Pathology Reveals Extracellular-Matrix Imaging Biomarkers of Therapy Response in Preclinical Breast Cancer.Cancers · 2026
- Near-infrared fluorescence imaging-guided surgery using cRGD-ZW800 to improve surgical resection margins in oral cancer: a phase I/II feasibility trialNature Communications · 2026
- REZCUE: Rescuing 3D spatial omics from archived FFPE tissuebioRxiv · 2026
- A pipeline for quantifying cell damage in whole-slide fluorescence images of skeletal muscle.Methods (San Diego, Calif.) · 2026
- Single-cell spatial pharmacobiology identifies conserved stromal barriers to therapeutic antibody delivery in human solid tumorsNature Biotechnology · 2026