Mechanical and multi-radiation shielding performance of concrete optimized with activated carbon and silica fume
Hamada Abd El-Rahman, Mohamed Y. M. Mohsen, M. A. Yousef, A. M. Abdelmonem, Wageeh Ramadan, Hamada H. Kora, A. Abdelghafar Galahom
Key points
From the paper's conclusion- This study investigates the effects of activated carbon (AC) and silica fume (SF) as partial cement replacements on the fresh properties, mechanical performance, and gamma-ray shielding efficiency of concrete cured for 28 and 56 days.
Abstract
Concrete plays a critical role in nuclear reactors by providing structural support and serving as a primary barrier against ionizing radiation. This study investigates the effects of activated carbon (AC) and silica fume (SF) as partial cement replacements on the fresh properties, mechanical performance, and gamma-ray shielding efficiency of concrete cured for 28 and 56 days. AC was incorporated at 1–6% by cement weight, while SF was used at a fixed dosage of 10%. Slump tests showed reduced workability for all modified mixtures due to the high surface area and water demand of AC and SF. Mechanical testing revealed that compressive strength increased with AC addition up to an optimum range of 2–4%, with further enhancement achieved in hybrid AC–SF mixtures; the highest gains were observed for combinations of AC and SF, while SF alone significantly improved both compressive and splitting tensile strengths. Gamma-ray attenuation was evaluated experimentally (0.1218–1.408 MeV) and validated using both XCOM theoretical data and MCNPX simulations based on Linear Attenuation Coefficient (LAC) and Mass Attenuation Coefficient (MAC), which showed good agreement with experimental data (relative deviation < 7%). Following model validation in the experimental energy range, these simulations were extended up to $$15 MeV$$ to generate theoretical predictions for complex shielding parameters ( $${Z}_{eff}$$ , $${N}_{eff}$$ , $${Z}_{eq}$$ ) and fast neutron removal cross-sections ( $${\Sigma}_{R}$$ ) without requiring additional costly experimental setups. Results indicate that optimized AC–SF mixtures, particularly the 2% AC + 10% SF hybrid, successfully balance structural integrity with superior multi-radiation shielding efficiency. The results demonstrate that optimized AC–SF concrete mixtures can simultaneously enhance mechanical integrity and gamma-ray shielding efficiency, making them promising candidates for structural radiation-shielding applications in nuclear facilities.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mechanical, microstructural, and radiation shielding characteristics of sustainable high-strength concrete incorporating recycled wastes blended powdersScientific Reports · 2025
- Durability and radiation shielding performance of blended cement mortar under increased ambient temperature and sulfate exposure in arid environmentsScientific Reports · 2025
- Review on radiation-shielding concrete: Advances in aggregate characterization, performance evaluation, and predictive modeling.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Radiation shielding performance of rare earth element-doped concrete against gamma rays, neutrons, and charged particlesRadiation effects and defects in solids · 2025
- Radiation shielding performance and mechanical behavior of hybrid fiber-reinforced sustainable concrete.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Enhancement of gamma radiation shielding performance of heavyweight concrete using slag and Direct Reduced Iron (DRI)Journal of Umm Al-Qura University for Engineering and Architecture · 2026