Scientific Reports

Heart rate response and clinical determinants of Glittre activities of daily living test performance in pediatrics with cystic fibrosis

Cemile Bozdemir, Elif Kocaaga, Haluk Tekerlek, Deniz Inal-Ince, Hulya Arikan, Melda Saglam, Naciye Vardar-Yagli, Ebru Calik,

Observational

Key points

From the paper's conclusion
  • The Pediatric Glittre Activities of Daily Living Test (TGlittre-P) is a field test designed to assess the functional performance of activities of daily living (ADL) in pediatric patients with cystic fibrosis (CF).

Abstract

The Pediatric Glittre Activities of Daily Living Test (TGlittre-P) is a field test designed to assess the functional performance of activities of daily living (ADL) in pediatric patients with cystic fibrosis (CF). However, the effects of TGlittre-P on heart rate response and the clinical determinants of test performance in this population remain insufficiently understood. To compare the heart rate response elicited by the TGlittre-P and the six-minute walk test (6MWT), and to identify pulmonary and extrapulmonary factors associated with TGlittre-P performance in pediatric patients with CF. Fifty-four pediatric patients with CF (mean age = 14.46 ± 2.16 years, 31 females and 23 males) were included in this cross-sectional study. ADL performance was assessed using the TGlittre-P, and functional capacity was assessed using the 6MWT. Pulmonary function, including forced expiratory volume in one second (FEV₁) and forced vital capacity (FVC), maximal inspiratory and expiratory pressure (MIP and MEP, respectively), handgrip strength (HGS %) and quadriceps muscle strength (QMS %) were measured. A multiple linear regression analysis model was used to determine independent predictors of TGlittre-P performance. The mean TGlittre-P duration was 2.00 ± 0.53 min. There was agreement between recorded peak heart rate (HRpeak) responses during the TGlittre-P and 6MWT (mean difference: -2.33%, with limits of agreement ranging from − 41.19 to 36.52). HRpeak (bpm), HRpeak (% predicted HRmax), and pre-to-post changes in systolic and diastolic blood pressure (mmHg), oxygen saturation (%), and perceived effort were not different between TGlittre-P and 6MWT (p > 0.05). TGlittre-P duration (min) correlated with 6MWT distance (m), FEV1 (%), FEV1z-score, FVC (%), FVC z-score, MIP (cmH2O), MEP (cmH2O), HGS (%) and QMS (%) (p < 0.05). The FEV1 z-score, height z-score and sex were predictors for TGlittre-P duration (min) [Adjusted R2 = 0.402, F(3, 53) = 11.755, p < 0.001, constant = 1.625]. No significant differences were observed in the measured heart rate response between the TGlittre-P and 6MWT. TGlittre-P performance is strongly associated with pulmonary function and respiratory and peripheral muscle strength. Airway obstruction was the strongest predictor of TGlittre-P performance in this population.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers