A personalized 2D/3D image registration pipeline for automated knee registration using single-plane moving fluoroscopy
Jinhao Wang, Xia Li, Saša Ćuković, Florian Vogl, William R. Taylor
Key points
From the paper's conclusion- In this study, we present a personalized 2D/3D image registration pipeline for automated registration of knee fluoroscopic images acquired using single-plane moving fluoroscopy.
Abstract
Accurate knee joint kinematics are essential for biomechanical research and clinical assessment. Single-plane fluoroscopy is one of the most accurate tools for measuring in vivo joint motion, but manual estimation of three-dimensional bone pose from individual fluoroscopic frames remains labor-intensive and time-consuming. In this study, we present a personalized 2D/3D image registration pipeline for automated registration of knee fluoroscopic images acquired using single-plane moving fluoroscopy. The proposed framework combines pose standardization across acquisition sessions, subject-specific learning-based pose estimation, and differentiable-rendering-based pose refinement. Tested using fluoroscopic datasets of both natural knees and knee implants together with a PyTorch3D-based differentiable renderer, we trained subject-specific pose estimation networks for both anatomy types. Evaluation against manually matched reference poses showed mean initial in-plane translation differences of approximately 1.1–2.1 mm and geodesic rotation differences of 1.3–3.6 $$^\circ$$ with mask-only input, while out-of-plane translation differences remained larger, as expected in single-plane imaging. Gradient-based refinement using gradient correlation coefficient (GCC) further reduced the disagreement with the manual reference poses, resulting in sub-millimetre in-plane translation differences and sub-degree rotational differences, with over 95% of test frames satisfying the predefined success criterion that both the femoral and tibial registrations had absolute in-plane translation differences below 1 mm in both $$T_x$$ and $$T_y$$ and a geodesic rotation difference below 1 $$^\circ$$ . These results quantify agreement with the existing manual registration workflow rather than independently validated anatomical pose accuracy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Two-dimensional to three-dimensional knee reconstruction from radiographs and fluoroscopy: A systematic review of methods and accuracy (1995-2025).PloS one · 2026
- In vivo tibiofemoral kinematic changes before and 6 months after anterior cruciate ligament reconstruction assessed with biplanar dynamic fluoroscopy: an exploratory single-arm pilot studyFrontiers in Bioengineering and Biotechnology · 2026
- Bridging the Markerless Tracking Validation Gap: Intraoperative X-ray Workflow IntegrationarXiv · 2026
- A Practical Pipeline for Patient-Specific Musculoskeletal Modeling: A Comprehensive MRI-Based Framework.Medical engineering & physics · 2026
- Rapid patient-specific neural networks for X-ray to volume registration.Nature · 2026
- TP1.4 Frame-by-Frame Analysis of Dynamic Acetabular Coverage During Operative-Stance in Femoroacetabular ImpingementJournal of Hip Preservation Surgery · 2026