Physics-constrained generative digital twin for early leakage detection in nitrogen accumulators in governor control systems at hydroelectric power plants
Taha Selim Ustun, Pampa Sinha, Mehmet Akif Butuner, Erkan Koc, Dogan Gezer
Key points
From the paper's conclusion- The corrected health index is bounded by 1.0, and cycle-level indicators identify the Month-4 warning transition before a conventional pressure-threshold response.
Abstract
Nitrogen pre-charge loss in hydropower governor accumulators is a slow but critical degradation process that weakens hydraulic energy storage, reduces pressure-retention time, increases pump cycling, and accelerates thermal–mechanical stress. Conventional pressure-threshold SCADA alarms can miss the early stage because oil pressure may remain inside the operating band while waveform dynamics deteriorate. This paper proposes a SCADA-calibrated physics-constrained generative digital twin for early nitrogen leakage diagnosis. Limited anonymized field-SCADA observations are used only as calibration anchors for pressure set-points, pump-ON duration, pump-OFF retention, temperature range, and the fast-rise/slow-decay waveform; they are not presented as a complete labeled leakage dataset. The evaluation uses 80,000 physics-constrained synthetic training records and 20,000 independently generated synthetic test records per run, balanced across eight degradation months. Train and test records are produced with disjoint seeds and no shared cycles or residual draws. Across five independent generation-and-training runs, Random Forest gives the best pressure-prediction performance, with R 2 = 0.999731 ± 0.000004, MAE = 0.0856 ± 0.0007 bar, RMSE = 0.1074 ± 0.0007 bar, and 96.78 ± 0.18% of samples within 1% of the 23-bar operating span (0.23 bar). The corrected health index is bounded by 1.0, and cycle-level indicators identify the Month-4 warning transition before a conventional pressure-threshold response. The framework therefore supports earlier inspection and nitrogen-recharge planning, helping operators reduce avoidable pump cycling, maintenance escalation, and the risk of unplanned governor-system outages, while explicitly distinguishing SCADA calibration from synthetic diagnostic evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic of erosive cavitation in hydraulic turbines from indirect measurements using SCADA data with uncertainty quantificationResults in Engineering · 2026
- A Scalable AI-Driven Digital Twin Framework for Hydroelectric Power PlantsHydropower · 2026
- Unsupervised Multi-Sensor Condition Monitoring of AODD Pump Systems Using Physics-Informed Health Indices and Gaussian Mixture Models.Sensors (Basel, Switzerland) · 2026
- Leakage-Aware and Regime-Based Evaluation of SCADA-Driven Wind-Turbine-Power Prediction Using Ensemble Machine LearningEnergies · 2026
- Accurate Classification of Minor Leaks in Primary Loop Systems Using a Multi-Scale Attention Temporal Convolutional Autoencoder.Sensors (Basel, Switzerland) · 2026
- Attributing Sensor Deviations to Degradation, Weather, or Attack in Oilfield Digital Twins: A Simulation Study of Probabilistic Attribution and Cost-Based DecisionsarXiv · 2026