Scientific Reports

From parameter screening to decision making: an integrated Taguchi–ANOVA, ANN–GA and AHP framework for optimization of a dual-core SPR driven PCF SARS-CoV-2 biosensor

Vikas Chandra Maurya, Anshu D Varshney, Suneet Kumar Awasthi

Key points

From the paper's conclusion
  • Surface plasmon resonance (SPR) driven dual core photonic crystal fiber (PCF) biosensor design for detection of SARS-CoV-2 under the framework of integrated Taguchi with analysis of variance (ANOVA) and artificial neural network (ANN) with genetic algorithm (GA) along with analytic hierarchy process (AHP) is proposed.

Abstract

Surface plasmon resonance (SPR) driven dual core photonic crystal fiber (PCF) biosensor design for detection of SARS-CoV-2 under the framework of integrated Taguchi with analysis of variance (ANOVA) and artificial neural network (ANN) with genetic algorithm (GA) along with analytic hierarchy process (AHP) is proposed. First, Taguchi approach is used for optimization of all seven geometrical parameters of the structure yielding maximum wavelength sensitivity, ANOVA is applied for statistical analysis of parameters on the performance of the sensor. The statistical analysis carried by ANOVA is cross verified by AHP. Further optimization of geometrical parameters done by Taguchi is validated by ANN integrated with GA. The validation results of this approach endorses optimized geometrical parameters as $$d_c = 0.42~\mu \textrm{m}$$ , $$d_1 = 0.62~\mu \textrm{m}$$ , $$d_2 = 0.88~\mu \textrm{m}$$ , $$d_3 = 1.66~\mu \textrm{m}$$ , $$\Lambda = 1.751~\mu \textrm{m}$$ , $$t_g = 45~\textrm{nm}$$ , and $$t_{\mathrm {TiO_2}} = 18~\textrm{nm}$$ . The maximum calculated values of wavelength sensitivity of the optimized structure which can sense the analyte of RI range from 1.33 to 1.38 in step length of 0.001 are 27000 nm / RIU and $$1{,}07000~\mathrm {nm/RIU}$$ corresponding to $$1^{st}$$ and $$2^{nd}$$ order SPP modes respectively. The corresponding resolution values of the structure are $$3.7\times 10^{-6}$$ RIU and $$9.3\times 10^{-7}$$ RIU . Moreover numeric values of other performance evaluating parameters like figure of merit (FOM) and amplitude sensitivity obtained from the data of this optimized structure are also impressive. This study lay out the foundation of designing an efficient photonic devices whose architecture depends upon multiple parameters by encouraging the application of mathematical modeling and machine learning framework.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers