A dual-stage self-attention hybrid convolutional neural network-gated recurrent unit architecture for real-time power quality disturbance diagnosis
Indu Sekhar Samanta, Buddhadeva Sahoo, Pravat Kumar Rout, Sarthak Mohanty, Sumit Kumar Jha, Kunjabihari Swain, Murthy Cherukuri
Key points
From the paper's conclusion- In this proposed work, a novel dual-stage hybrid architecture based on convolutional neural networks (CNNs) and gated recurrent units (GRUs) augmented by self-attention at both stages for real-time high performance PQD classification is presented.
Abstract
The increased adoption of the smart grid (SG) infrastructure to overcome the limitations of traditional grid have faced growing challenges for real-time monitoring and classification of features due to the complexity and dynamic nature of power quality disturbances (PQDs). In particular, when PQDs overlap each other, traditional approaches relying on signal processing techniques tend to lose the dynamic, non-periodic characteristics which define certain PQDs. In this proposed work, a novel dual-stage hybrid architecture based on convolutional neural networks (CNNs) and gated recurrent units (GRUs) augmented by self-attention at both stages for real-time high performance PQD classification is presented. This novel hybrid architecture is allows for spatial and temporal feature extraction from electrical power signals, overcoming the weaknesses encountered in traditional approaches. In contrast to previous models that consider either local or sequential patterns independently, the proposed architecture combines both techniques enabling a more robust and computationally-efficient architecture demonstrates software-level real-time inference (21 ms) and provides a computationally efficient architecture suitable for future embedded deployment. The experimental outcomes on the benchmark databases compared to the state-of-the-art convolutional neural network-long short-term memory (CNN-LSTM) architecture offers improved execution time of 21 ms and a classification accuracy of 98.6%. It also outperforms both traditional CNN architecture with improved latency and high accuracy proposing it as a viable alternative for smart grid use cases like phasor measurement units (PMUs), microcontroller-based devices, etc.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Composite power quality disturbance identification method considering confidence correctionFrontiers in Energy Research · 2026
- Automatic Power Quality Events Classifier based on hybrid CNN–LSTM network and multisine fitting algorithmMeasurement · 2026
- Power quality disturbance identification using hybrid deep learning in renewable energy systemsScientific Reports · 2025
- Attention-enhanced residual networks for real-time multi-label power quality disturbance classification with fast iterative filteringApplied Energy · 2025
- Deep transfer learning approach for the classification of single and multiple power quality disturbancesScientific Reports · 2025
- Voltage sag and short interruption edge-side tracing model based on a spiking spatiotemporal causal graph convolutional networkAIP Advances · 2026