The replicability of real-world evidence for the surgical treatment of proximal humeral fractures in older patients evaluated using sceptical p-value.
Jeanette Koeppe, Karen Fischhuber, Josef Stolberg-Stolberg, Ursula Marschall, Michael J Raschke, Andreas Faldum, J Christoph Katthagen
Department of Epidemiology and Biostatistics, Public and Global Health, Medical University Lausitz - Carl Thiem, Thiemstr. 111, Cottbus, 03048, Germany. j.koeppe@mul-ct.de. · Institute of Biostatistics and Clinical Research, University of Münster, Schmeddingstr. 56, Münster, 48149, Germany.
Key points
From the paper's conclusion- Overall, 7 (64%) of the 11 evaluated endpoints were successfully replicated.
Abstract
The replicability of study results plays a central role, particularly in the context of real-world evidence (RWE). However, the evaluation of the agreement between two study results is not straightforward and different metrics are available. As an example for RWE, the surgical treatment of proximal humeral fractures in older patients using locked plate fixation (LPF) or reverse total shoulder arthroplasty (RTSA) was analyzed by two different studies based on the data of the largest German health insurance company, but the generalizability of the results should be further addressed. Independent data of a different German insurance company were used to emulate two existing studies evaluating different short- and long-term safety endpoints after surgical treatment of proximal humeral fracture in older patients using RTSA vs LPF. Study protocol was a priori registered. The sceptical p-value was used to judge the agreement between known original effect estimate (OES) and the observed emulated treatment effect estimate (EES) and compared to other existing binary agreement metrics. Overall, 7 (64%) of the 11 evaluated endpoints were successfully replicated. The Pearson correlation coefficient ( = 0.97) and the intra-class correlation coefficient (ICC3 = 0.94) indicated a good, positive correlation between original and emulation study. OES was successfully replicated for all short-term endpoints and surgical complications during follow-up (all). Furthermore, the treatment effect for surgical complications during follow-up was successfully replicated using an independent data base. The sceptical p-value was a useful and well-interpretable metric to evaluate the agreement between original and emulation study.Trial registration: A priori registered at ClinicalTrials.gov (Identifier: NCT06537024).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reverse Shoulder Arthroplasty Versus Non-operative Treatment for Displaced Three- and Four-Part Proximal Humeral Fractures in Older Adults: A Systematic Review and Meta-Analysis.Cureus · 2026
- Reverse total shoulder arthroplasty vs non-operative management for proximal humerus fracture: Systemic review and meta-analysis of comparative studies.Journal of orthopaedic surgery (Hong Kong) · 2026
- Intramedullary nailing versus locking plate fixation for proximal humerus fractures: a systematic review and meta-analysis of randomized controlled trials.Musculoskeletal surgery · 2026
- Comparative efficacy and safety of locking intramedullary nails versus locking plates for displaced proximal humeral fractures : a meta-analysis and trial sequential analysis of randomized controlled trial.Bone & joint open · 2026
- No Difference in Revision Risk for Uncemented Humeral Stems Compared to Cemented Humeral Stems in Reverse Total Shoulder Arthroplasty for Proximal Humerus Fracture: A Registry-Based Cohort Study.Journal of shoulder and elbow surgery · 2026
- Systematic Data Fitness Assessment Improves Validity and Replicability of Research Using Real-World DatamedRxiv · 2026