Development and evaluation of a multi-axis loading simulator for the spine, pelvis, and lumbosacral region.
Toni Wendler, Robin Heilmann, Hannah Müller, Jean-Pierre Fischer, Andreas Höch, Christian Kleber, Christoph-E Heyde, Stefan Schleifenbaum
Department of Orthopedic, Trauma and Plastic Surgery, University of Leipzig Medical Center, Liebigstraße 20, D-04103, Leipzig, Germany. toni.wendler@medizin.uni-leipzig.de. · Department of Orthopedic, Trauma and Plastic Surgery, University of Leipzig Medical Center, Liebigstraße 20, D-04103, Leipzig, Germany.
Key points
From the paper's conclusion- This study therefore aims to develop and validate a versatile biomechanical loading simulator capable of reproducing common test protocols, improving the comparability of results and enabling a systematic evaluation of innovative implant and treatment concepts.
Abstract
The treatment of injuries and disorders of the pelvis, lumbar spine and lumbosacral junction remains challenging due to rising case numbers, complex anatomy and high biomechanical demands. Despite advances in surgical techniques and implant design, problems regarding stability and long-term functionality persist, requiring individualized solutions and a thorough biomechanical assessment. Biomechanical studies are essential for assessing implant performance under physiological conditions. This study therefore aims to develop and validate a versatile biomechanical loading simulator capable of reproducing common test protocols, improving the comparability of results and enabling a systematic evaluation of innovative implant and treatment concepts. A loading simulator with three active degrees of freedom (driven by controlled servo motors) and two passive degrees of freedom (low-friction linear slide bearings) was developed. Five pelvic specimens with an intact lumbar spine up to L2 were first subjected to a range-of-motion (ROM) analysis and subsequently to cyclic dynamic loading to test the functionality of the simulator. The ROM analysis resulted in mean absolute deviations (MAD) of less than 7.50 N for all translational degrees of freedom (DOF) and less than 0.87 Nm for the two unloaded rotational DOF. The maximum moment in the loading direction deviated by a MAD of less than 0.18 Nm. The cyclic loading protocol was achieved in the vertical force direction (60% body weight (BW)) with a MAD of less than 0.76% BW. The maximum and minimum moments to be applied in extension-flexion (± 5 Nm) were realized with a MAD of less than 0.23 Nm. In summary, the simulator developed demonstrates a high degree of accuracy, reproducibility and flexibility. It therefore provides a suitable platform for the biomechanical investigation of implants and stabilization concepts in the pelvic and spinal regions and offers a promising basis for future experimental studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validation of lumped-parameter models of the human lumbar spine using in vivo driving-point compliance data during spinal manipulation.Biomechanics and modeling in mechanobiology · 2026
- Modular Cage-Type Prosthetic Construction for Lumbar Intervertebral Reconstruction: A Computer-Aided Design-Based Geometric Design and Finite Element Analysis Study.Cureus · 2026
- Lumbar Spine Motion Analysis: A Systematic Review of Segmental and Global Range of Motion.Cureus · 2026
- Response of the lumbar spine in combined flexion and axial compression up to failure: Postmortem human subject experiments and human body model assessment.Traffic injury prevention · 2026
- Design and implementation of a paradigm-specific cervical manipulation simulator with objective force-angle feedback.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026
- Integrated Study of the Distal Femur Biphasic Plate: Exploring In Vivo, In Vitro, and In Silico Methodologies.Annals of biomedical engineering · 2026