Scientific reports

The role of dataset integrity, calibration and signal quality in neural network-based blood pressure estimation.

Christian Fritzsche, Veit Senner

TUM School of Engineering and Design, Professorship of Sport Equipment and Sport Materials, Technical University of Munich, Munich, Germany. christian.fritzsche@tum.de. · TUM School of Engineering and Design, Professorship of Sport Equipment and Sport Materials, Technical University of Munich, Munich, Germany.

Review

Key points

From the paper's conclusion
  • These findings suggest that dataset integrity and proper calibration may matter more than model architecture in cuffless BP estimation.

Abstract

Cuffless blood pressure (BP) estimation via photoplethysmography (PPG) and machine learning has been widely studied, yet reported accuracy remains below clinically acceptable levels, limiting adoption in sport, ambient living, and telemedicine. This study systematically examines potential error sources underlying these performance gaps, with emphasis on: dataset selection, signal synchronization, subject-specific calibration, and data leakage. Three neural networks-a multilayer perceptron (MLP_BP), residual network (Res_BP), and temporal convolutional network (TCN_BP)-were evaluated on two curated public datasets derived from MIMIC III and VitalDB, differing primarily in signal synchronization. MLP_BP uses scalar features from ECG and PPG signals, including pulse arrival time, heart rate, and variability; Res_BP and TCN_BP additionally process PPG signals. Subject-wise splits prevent data leakage, and calibration is applied using three to nine initial reference measurements per subject. Models trained on VitalDB consistently outperform those trained on MIMIC III, particularly for systolic BP, underscoring the importance of synchronized signals. Subject-specific calibration improves performance, with diminishing returns beyond three measurements. Calibrated models reach clinically acceptable accuracy for diastolic BP, while systolic BP remains challenging using PPG alone. These findings suggest that dataset integrity and proper calibration may matter more than model architecture in cuffless BP estimation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

The role of dataset integrity, calibration and signal quality in neural network-based blood pressure estimation — Science Skim