Design and implementation of a hybrid machine learning framework for predicting heart rate status
Mahsa Emami, Neda Salehbagheri, Saman Rajebi, Siamak Pedrammehr, Kimia Shirini
Sadra Institute Of Higher Education · Tabriz Islamic Arts University
Key points
From the paper's conclusion- The proposed framework contributes to improving real-time heart rate monitoring by addressing computational constraints and enabling efficient deployment on embedded platforms.
Abstract
Real-time accurate evaluation of heart rate status during physical activity is a critical requirement in physiological analysis, performance enhancement, and early warning systems for cardiovascular diseases. In this work, a lightweight hybrid machine learning model for classifying the status of heart rate during physical activities into normal and warning levels using a combination strategy of Multilayer Perceptron, Naïve Bayes, and K-Nearest Neighbors algorithms in a weighted voting-based ensemble model is presented. The model analyzes a set of physiological and environmental parameters such as temperature, humidity, speed, incline, and activity time. Before embarking on model development, a thorough statistical analysis of available data was performed, which involved descriptive statistics, density analysis, normality tests using Shapiro-Wilk tests, and both parametric and non-parametric hypothesis tests to establish the discriminative power of all input variables in spite of non-normality. Every individual base classifier model was tested for performance using a fixed split of 70/15/15 for training, validation, and testing, and their respective strengths were tapped using a weighted voting mechanism based on relief factor analysis. The simulation outcome shows that the proposed ensemble classifier performs better than standalone classifiers in achieving an accuracy of up to 96.67%, an F1-score of 96.66%, and an MCC of 0.9354, which is a manifestation of excellent classification balance and statistical significance. The proposed system was also tested on an embedded system developed using an Arduino platform for real-time processing, and it achieved an accuracy of 90.83% and an MCC of 0.8167. The performance degradation is due to sensor noises and limited numerical precision in an embedded system. The proposed framework contributes to improving real-time heart rate monitoring by addressing computational constraints and enabling efficient deployment on embedded platforms.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Incremental Value of 24-Hour Ambulatory Electrocardiogram-Derived Heart Rate Variability in Machine-Learning Prognostic Models for Heart Failure.International heart journal · 2026
- An artificial intelligence-based prediction for suitable sport exercise recommendation using BMI and heart rateFrontiers in Big Data · 2026
- AI ‐Enabled Intelligent Monitoring of Mental Health Indicators During Physical Activity Among Jiangsu Vocational College StudentsEngineering Reports · 2026
- Explanatory Versus Predictive Modeling in Heart Rate Variability Research: Nonlinearity, Model Choice, and Machine LearningApplied Sciences · 2026
- Generalize Then Personalize: Wearable-Based Heart Rate Forecasting Under Scarce Ruck-March DataarXiv · 2026
- AI-based personalized exercise and health recommendation system using hybrid modeling.Frontiers in artificial intelligence · 2026