Sustainable high-throughput microwell spectrophotometric methods for avapritinib quality control via charge-transfer complexation
Awadh M. Ali, Mohammed S. Alsalhi, Weam M. Othman, Antonio Frontera, Waleed Alahmad, Ibrahim A. Darwısh
King Saud University · Misr University for Science and Technology
Key points
From the paper's conclusion- With a substantially higher throughput of ~ 500 samples/hour and minimal solvent consumption (200µL/well), the proposed MW-SPMs offers a rapid, sustainable, and cost-effective alternative to conventional chromatographic and spectrofluorimetric techniques for routine pharmaceutical analysis, aligning with multiple United Nations Sustainable Development Goals.
Abstract
Avapritinib (AVA) is a breakthrough targeted therapy as the first potent inhibitor approved for gastrointestinal stromal tumors (GIST) with PDGFRA D842V mutations. It lacks convenient analytical methods for routine quality control. This study addresses this gap by developing and validating two novel, green, high-throughput microwell spectrophotometric methods (MW-SPMs) for AVA quantification in pharmaceutical tablets-representing the first employment of charge-transfer complexation for AVA analysis. The methods exploit rapid charge-transfer complex (CTC) formation between AVA (electron donor) and two π-acceptors: 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) and chloranilic acid (CLA). The reactions, conducted in 96-well plates using only 200 µL total volume, yielded stable colored complexes with absorption maxima at 460 nm and 520 nm for the reactions with DDQ and CLA, respectively. Following ICH-compliant optimization and validation, both methods demonstrate excellent linearity (3.13-100 µg/well for DDQ; 6.25-100 µg/well for CLA), precision (RSD ≤ 1.8%), and accuracy (recoveries: 98.0-101.7%). Job's method confirmed 1:1 stoichiometry, while density functional theory (DFT) uniquely revealed the molecular basis for the stronger binding affinity of DDQ over CLA through dominant π-π stacking and hydrogen-bonding interactions, demonstrating how computational analysis can guide reagent selection in analytical method development. A comprehensive multi-metric sustainability assessment-utilizing ten tools including AES, AGREE, BAGI, RGB, and RAPI-confirmed the methods' excellent greenness (e.g., AES score = 90), superior practicality, and robust analytical performance, achieving a high White Index of 94.2%. With a substantially higher throughput of ~ 500 samples/hour and minimal solvent consumption (200µL/well), the proposed MW-SPMs offers a rapid, sustainable, and cost-effective alternative to conventional chromatographic and spectrofluorimetric techniques for routine pharmaceutical analysis, aligning with multiple United Nations Sustainable Development Goals.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Response surface methodology-optimized microwell spectrophotometric method for saxagliptin quantitation: a sustainable, high-throughput approach for pharmaceutical quality control.Analytical methods : advancing methods and applications · 2026
- Green chemistry integrated quality by design based RP-HPLC method for analysis of Itraconazole in pharmaceutical formulationsDiscover Green Chemistry · 2026
- "Green spectrophotometric determination of rupatadine, its toxic impurity, and methyl paraben: comparative AI-assisted univariate versus multivariate chemometrics".Scientific reports · 2026
- DFT-ML-Based Property Prediction of Transition Metal Complex Photosensitizers for Photodynamic TherapyACS Omega · 2025
- Development and Validation of a Quality by Design‐Driven RP‐HPLC Assay Method for the Simultaneous Estimation of Lenalidomide and Sonrotoclax in Bulk Drug Substance, with a Six‐Edged Sustainability AssessmentSEPARATION SCIENCE PLUS · 2026
- Terbium-modified poly(diphenylamine orange) sensor enabling sustainable monitoring of imatinib: Voltammetric and DFT insights.Talanta · 2026