◆ Frontiers in dental medicine2026-01-01

Effect of different scaling instruments on the roughness of esthetic resin composite restorations: an in vitro study.

Abdulkareem Alhumaidan, Turki Alshehri, Shahad T Alameer, Dhai Albishri, Abdullah Al Madani, Mohammed Al Qranei, Hoda Albaqawi, Abdulrahman A Balhaddad

一句话结论 · In one sentence

Within the limitations of the study, plastic scalers caused the least surface alteration and may be considered the most conservative option for maintaining the surface smoothness of resin composites.

原始摘要(英文原文)· Original abstract
OBJECTIVES: This in vitro study aimed to evaluate the effect of different scaling methods on the roughness of various resin composites used in anterior teeth. METHODS: Seven commercially available resin composite materials were tested: 3M™ Filtek™ Z350 XT, Beautifil II, and Beautifil II LS, G-ænial Anterior, IPS Empress Direct, Tokuyama PALFIQUE LX5, Vittra APS FKG. Disc-shaped specimens (6 mm in diameter and 2 mm in thickness) were prepared using a 3D-printed mold. A total of 30 specimens per brand were fabricated and randomly divided into three sub-groups according to the scaling technique: stainless-steel hand scaler (metal scaling), plastic hand scaler (plastic scaling), and piezoelectric ultra-sonic scaler tip (ultra-sonic scaling). Baseline surface roughness values were measured using a non-contact optical profilometer. Each specimen was then subjected to 40 scaling strokes, and post-scaling surface roughness was remeasured using the same method. The change in average surface roughness was calculated. Two and One-way ANOVA with Tukey's post hoc test analyzed the data (α= 0.05). RESULTS: Both scaler method and resin composite type were determinant factors (p < 0.001) in modulating the roughness of resin composite restorations. Metal scaling consistently produced the greatest surface roughness change (ΔRa, µm) across all composites, with G-ænial Anterior recording the highest ΔRa value (2.23 ± 0.91 µm) and IPS Empress Direct the lowest (1.23 ± 0.82 µm). Plastic scaling resulted in the least ΔRa across all materials (range: 0.00-0.10 µm), with IPS Empress Direct recording the highest change (0.10 ± 0.08 µm) and G-ænial Anterior and Tokuyama PALFIQUE LX5 revealing almost no change. Ultra-sonic scaling produced intermediate roughness change, with G-ænial Anterior again recording the highest value (1.61 ± 0.98 µm). Metal scaling produced significantly higher ΔRa than both plastic and ultra-sonic methods in most resin composites (p < 0.05), while plastic and ultra-sonic groups were largely comparable. CONCLUSION: Within the limitations of the study, plastic scalers caused the least surface alteration and may be considered the most conservative option for maintaining the surface smoothness of resin composites.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Effect of different scaling instruments on the roughness of esthetic resin composite restorations: an in vitro study. — 科研速览 Science Skim