Noninvasive hemodynamic assessment of aortic coarctation: multimodal imaging based-computational fluid dynamics
Mengsi Hu, Xia Li, Huihui Wang, Yuezhong Zhang, Ximing Wang, Jiayi Liu, Zhenxia Mu, Peixian Gao,
Shandong University · Shandong Provincial Hospital
Key points
From the paper's conclusion- Here we developed a non-invasive computational fluid dynamics (CFD) modeling framework based on multidetector computed tomography angiography (MDCTA) and ultrasound-derived input parameters, which incorporated into a lumped parameter model (LPM) and validated the results against measurements obtained via cardiac catheterization, both preoperatively and postoperatively.
Abstract
The gold standard assessment of coarctation of aorta (CoA) was achieved invasively by cardiac catheterization, which is associated with several risks including radiation exposure. The present study aimed to validate a multimodal imaging-based non-invasive computational framework for assessment of trans-coarctation pressure gradients (PG) in patients with severe coarctation of the aorta (CoA). Here we developed a non-invasive computational fluid dynamics (CFD) modeling framework based on multidetector computed tomography angiography (MDCTA) and ultrasound-derived input parameters, which incorporated into a lumped parameter model (LPM) and validated the results against measurements obtained via cardiac catheterization, both preoperatively and postoperatively. We used conventional Doppler estimates to make these correlations and to compare their diagnostic performance in identifying critical PG. The results indicated that for 18 patients with severe CoA the CFD simulation exhibited better concordance and correlation with catheter measurements compared to Doppler gradients (pre-intervention: 58.44 ± 17.77 vs. 55.72 ± 19.71 vs.57.78 ± 18.02 mmHg; post-intervention: 17.94 ± 10.54 vs. 15.65 ± 5.15 vs.20.61 ± 7.43 mmHg). Specifically, the CFD-derived PG showed a stronger correlation with catheter measurements (pre-intervention r = 0.89, post-intervention r = 0.90) than did Doppler-derived PG (pre-intervention r = 0.71, post-intervention r = 0.30). This CFD framework facilitated reliable quantification of PG and visualization of hemodynamic forces in patient-specific geometric models, and suggesting its potential as a non-invasive and effective approach for the assessment of CoA.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validation of individualized flow simulations for determining the pressure gradient in patients with renal artery stenosismedRxiv · 2026
- Geometric Determinants of Post-stenotic Energetics in Coarctation of Aorta: Linking Centerline Morphology to Downstream Energy Loss.Annals of biomedical engineering · 2026
- Patient-specific hemodynamic assessment using experimental and computational approaches in anomalous aortic origin of the coronary artery: Case study.JTCVS techniques · 2026
- Computational assessment of fibromuscular dysplasia-related renal artery stenosisComputers in Biology and Medicine · 2025
- Uncertainty Quantification and Global Sensitivity Analysis of Patient-Specific Coronary Hemodynamics Under Unsteady Flow ConditionsarXiv · 2026
- Patient-Specific Computational Fluid Dynamics of Pulmonary Arterial Hemodynamics in Dogs with and Without Pulmonic Stenosis.Animals : an open access journal from MDPI · 2026