Strengthening of corroded RC slab–column joints using thin-ply hybrid FRP under punching shear
Ahmed M. Gomaa, Manar A. Ahmed, Sherif A. Khafaga, E. Lotfy, Sally Hosny
Egyptian Russian University · Suez Canal University
Key points
From the paper's conclusion- Overall, the findings suggest that thin-ply hybrid FRP, when optimally arranged, can be a practical option for partial recovery of PS capacity in moderately corroded RC slab–column joints; however, its effectiveness is influenced by corrosion extent, bond performance, and configuration, and therefore should not be generalized beyond the tested parameters.
Abstract
A comprehensive investigation into the punching shear (PS) strengthening behavior of corroded two-way reinforced concrete (RC) slabs using thin-ply glass/carbon hybrid FRP was conducted through an integrated experimental, numerical, and theoretical program. Eleven slab–column joints (SCJs) were cast and tested under monotonic loading to assess different external strengthening configurations. The experimental results indicated that hybrid thin-ply FRP improved PS capacity more effectively than single-material GFRP or CFRP systems within the tested conditions. Numerical analysis using ABAQUS was then carried out to evaluate the influence of strengthening parameters. The simulations showed that increasing the FRP layers beyond two, or thickness beyond approximately 0.6 mm, resulted in limited additional capacity due to premature debonding. The parametric study identified a skewed strip layout with a 50 mm offset from the column face and two hybrid layers (0.6 mm each) as the most effective configuration for the investigated geometry and corrosion level. Strengthening efficiency was observed to decrease as corrosion severity increased, reducing from 50.77% at 5% corrosion to 24.76% at 30%. Overall, the findings suggest that thin-ply hybrid FRP, when optimally arranged, can be a practical option for partial recovery of PS capacity in moderately corroded RC slab–column joints; however, its effectiveness is influenced by corrosion extent, bond performance, and configuration, and therefore should not be generalized beyond the tested parameters.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Strengthening of punching shear of flat slab–column connections through hybrid near‐surface mounted and externally bonded systems: Experimental, numerical, and analytical studyStructural Concrete · 2026
- Carbon Fiber-Reinforced Polymer Strengthening of Reinforced Concrete Beams: A Review of Flexural, Shear, and Impact-Related Techniques, Performance, and Failure MechanismsInfrastructures · 2026
- CFRP Strengthening for Progressive Collapse Mitigation of RC Flat SlabsBuildings · 2026
- The Behavior of Beams Reinforced with Patches Under Three-Point Bending: An Experimental InvestigationPolymers · 2025
- Effectiveness of FRP Strengthening on RC Columns with Multiple Structural Deficiencies: A Numerical InvestigationBuildings · 2026
- Structural effectiveness of NSM aluminum bars combined with UHPC/ECC overlays in strengthening RC slabs against punching shearCase Studies in Construction Materials · 2026