Key points
From the paper's conclusion- The suggested system is validated, taking balanced as well as unbalanced nonlinear loads, and the outcomes are contrasted with those obtained from an SHAF system based on the Type-1 Fuzzy Fractional Order PID Controller (T1FFOPIDC), which is also optimized using hPSOFA.
Abstract
Reactive Power & Harmonic compensation (RPHC) represents a crucial area of investigation within the domains of power engineering. While passive filters have traditionally been favored for mitigating harmonics, their size becomes impractical when addressing multiple harmonics. In contrast, active power filters offer enhanced performance and address the limitations of passive filters, albeit at a higher cost. This study introduces a Shunt Hybrid Active Filter (SHAF) designed for RPHC. In our approach, the Kalman Filter (KF) is utilized for estimation of reference current per-unit (PU) quantity and the current reference crest value, which are derived from a Type-2 Fuzzy Fractional Order PID Controller (T2FFOPIDC). The optimal parameters for the T2FFOPIDC are determined using an innovative hybrid Particle Swarm Optimization (PSO) Firefly Algorithm (hPSOFA), with a focus on minimizing the ITAE. The suggested system is validated, taking balanced as well as unbalanced nonlinear loads, and the outcomes are contrasted with those obtained from an SHAF system based on the Type-1 Fuzzy Fractional Order PID Controller (T1FFOPIDC), which is also optimized using hPSOFA. The compensation strategy employed in the SHAF differs from the conventional (id-iq) or (p-q) techniques, as it necessitates the current from the source side. Various performance metrics, including Reactive Power (Q), THD, and PFS, are assessed to evaluate the effectiveness of the proposed controller. Case studies reveal that the hPSOFA-T2FFOPIDC-based SHAF demonstrates superior RPHC compared to the hPSOFA-T1FFOPIDC-based SHAF across various operational scenarios. Furthermore, the performance of the proposed hPSOFA-T2FFOPIDC-SHAF has been experimentally validated using dSPACE.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Hybrid Compensation System Combining a Parallel LC Filter and a Shunt Active Power Filter Using Load-Conductance-Signal ControlEnergies · 2026
- Intelligent Power Quality Correction Using Predictive Models and Metaheuristic OptimizationEPJ Web of Conferences · 2026
- Enhanced jellyfish search-optimized cascaded fuzzy-FOPI control of a three-phase dynamic voltage restorer for power quality improvementScientific Reports · 2026
- Hybrid control approach of PV-Fed two-leg three-phase active power filter with harmonic compensation and reactive power injectionScientific African · 2026
- DSOGI-PLL and Moving Average Filter Based Control Method for Shunt Active Power FilterThe Eurasia Proceedings of Science Technology Engineering and Mathematics · 2026
- Power quality optimization framework for three phase microgrids with grid tied solar PV and battery storage under nonlinear loadsScientific Reports · 2025